Display group 19 with ignition on
WARNING: This page is about a different variant/trim than selected.
| Display group 019 -Quantity adjuster | ||||||
| Read measuring value block 19 | → | Indicated on display | ||||
| x.xxx V | x.xxx V | |||||
| 1 | 2 | 3 | 4 | Display zones | Specification | Evaluation |
| No display | --- | --- | ||||
| No display | --- | --- | ||||
| Voltage from Modulating Piston Displacement Sensor G149 (start position stop) | 4.150...4.740 V | |||||
| Voltage from Modulating Piston Displacement Sensor G149 (stop position stop) | 0.500...0.970 V | |||||