Display group 60 (Speed regulation) Adaptation EPC system * See note
WARNING: This page is about a different variant/trim than selected.
Readiness code
| Display group 60 (Speed regulation) Adaptation EPC system * See note | ||||||
|
||||||
|
||||||
| Read Measuring Value Block 60 | → | Indicated on display | ||||
| xx% | xx% | x | Text | |||
| 1 | 2 | 3 | 4 | Display zones | Specification | Evaluation |
| Adaptation condition (ADP runs, ADP OK or ADP ERROR) | ADP OK | --- | ||||
| Learning step counter | 0 to 8 | --- | ||||
| Throttle Drive Angle Sensor 2 (for Electronic Power Control (EPC)) G188 | 97 to 3% | --- | ||||
| Throttle Drive Angle Sensor 1 (for Electronic Power Control (EPC)) G187 | 3 to 93% | --- | ||||
* Adapting engine control module to throttle valve control module → Engine control module, adapting to throttle valve control module .
NOTE:
- For display zone 60:
- Matching the throttle valve control module is performed with ignition switched on.
- Engine control module is adapted to throttle valve control module when selecting display group 60 under function 04 "Basic setting". This adaptation must always be carried out when another throttle valve control module (or another complete engine) or another engine control module is installed.
- The counter counts up to 8 in display zone 3 during the adaptation.