Display group 119 (Charge pressure control)
WARNING: This page is about a different variant/trim than selected.
| Display group 119 (Charge pressure control) | ||||||
|
||||||
| Read Measuring Value Block 119 | → | Indicated on display | ||||
| xxxx RPM | x.x% | x.x% | xxx mbar | |||
| 1 | 2 | 3 | 4 | Display zones | Specification | Evaluation |
| Actual charge value Engine code AWW Engine code AWP | max. 1800 mbar max. 2200 mbar | --- | ||||
| Wastegate bypass regulator valve duty cycle | 0 to 100% | --- | ||||
| Boost pressure limitation | -15 to 160% | --- | ||||
| Engine speed (idling speed) Manual transmission Automatic transmission | 700 to 6800 RPM 640 to 6800 RPM | --- | ||||