LEMON Manuals: Even more car manuals for everyone
Home >> Volkswagen >> 2001 >> Jetta GL, 2.0 B >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 33 (1.8L - Engine Mechanical, Engine Code(S): AWD, AWW, AWP (A4 Platform)) >> 20 - Fuel supply >> Evaporative emissions (EVAP) system >> EVAP system, checking for leaks >> Function test

Function test

WARNING: This page is about a different variant/trim than selected.

Scan tool display:

Quick data transfer HELP
Select function XX

Scan tool display:

Read measuring value block
Enter display group number XXX

Scan tool display

Read measured value block 71 ->
Reed open Test OFF

Scan tool display

System in basic setting 71 ->
Reed open Test ON

Scan tool display

System in basic setting 71 ->
Reed closed Test ON

EVAP canister system test is initiated. First, function of reed contact (in Leak Detection Pump (LDP) V144 ) is checked by control module.

Scan tool display

System in basic setting 71 ->
Reed closed Syst. Test Test ON

After approx. 10 seconds, Leak Detection Pump (LDP) V144 is activated and generates pressure in fuel system.

Scan tool display

System in basic setting 71 ->
Reed open Syst. Test Test ON

After approx. 50 seconds, the test is initiated (this can take up to 120 seconds if there is insufficient pressure in the fuel system).

Scan tool display

System in basic setting 71 ->
Reed open Measurement Test ON

The Leak Detection Pump (LDP) V144 switches off and the time until the reed contact closes is measured by the control module.

Scan tool display

System in basic setting 71 ->
Reed closed END of measurement Syst. OK

Display field 3 specified value: END of measurement

Display field 4 specified value: Syst. OK

If the specifications are not obtained:

If specified values are achieved: