Home >> Volkswagen >> 2001 >> Golf GL, 2.0 B >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 37 (1.8L - Generic Scan Tool, Engine Code(S): AWP, AWW, AWD (A4 Platform)) >> 26 - Exhaust system, Emission controls >> Secondary Air Injection (AIR) System >> Secondary Air Injection (AIR) Solenoid Valve -N112- , checking

Secondary Air Injection (AIR) Solenoid Valve -N112- , checking

WARNING: This page is about a different variant/trim than selected.

Special tools, testers and auxiliary items required 

Test requirements 

Test procedure 

Start diagnosis 

NOTE:
  • Voltage is supplied to the Secondary Air Injection (AIR) Solenoid Valve N112 from the Fuel Pump (FP) Relay J17.

Procedure 

Fig 1: Secondary Air Injection Solenoid Valve N112 Electrical Harness Connector
GW00001036Courtesy of VOLKSWAGEN UNITED STATES, INC.

Checking internal resistance 

Fig 2: Checking Resistance Between Terminals Of Solenoid Valve
GW00001037Courtesy of VOLKSWAGEN UNITED STATES, INC.

If the specified value was not obtained:

If the specified value was obtained:

Checking voltage supply 

Switch the ignition on.

Fig 3: 2-Pin Electrical Harness Connector & Terminals
GW00001023Courtesy of VOLKSWAGEN UNITED STATES, INC.

Specified value: battery voltage.

Switch the ignition off.

If the specified value was not obtained:

Checking wiring 

If the manufacturers test box is being used. Perform the following step.

If the manufacturers test box is not being used. Perform the following step.

Fig 4: 2-Pin Electrical Harness Connector & Terminals
GW00001023Courtesy of VOLKSWAGEN UNITED STATES, INC.
Secondary Air Injection (AIR) Solenoid Valve N112 electrical harness connector terminal Motronic Engine Control Module (ECM) J220 electrical harness connector T121 terminal or test box socket
2 9

Specified value: 1.5 Ω Max.

If the specification was not obtained:

If no malfunction is detected in the wiring:

If the DTC does not return:

Repair complete, Generate readiness code. Refer to →Readiness Code  .

If the DTC does return and no malfunction is detected in the wiring and the voltage supply was OK:

Final procedures 

After repair work, the following work steps must be performed in the following sequence:

  1. Check the DTC memory.
  2. If necessary, erase the DTC memory.
  3. If the DTC memory was erased, generate readiness code.

End diagnosis