Display group 118 - Charge pressure control
WARNING: This page is about a different variant/trim than selected.
| Display group 118 - Charge pressure control | ||||||
|
||||||
| Read Measuring Value Block 118 | → | Indicated on display | ||||
| xxxx RPM | xxx.x ° C | xxx.x% | xxx mbar | |||
| 1 | 2 | 3 | 4 | Display zones | Specification | Evaluation |
| Actual charge value Engine code AWW Engine code AWP | max. 1800 mbar max. 2200 mbar | --- | ||||
| Wastegate bypass regulator valve duty cycle | 0 to 95% | --- | ||||
| Intake air temperature | max. 110 ° C | --- | ||||
| Engine speed (idling speed) Manual transmission Automatic transmission | 700 to 6800 RPM 640 to 6800 RPM | --- | ||||