Display group 116 - Charge pressure control
WARNING: This page is about a different variant/trim than selected.
| Display group 116 - Charge pressure control | ||||||
|
||||||
| Read Measuring Value Block 116 | → | Indicated on display | ||||
| xxxx RPM | x.x% | x.x% | x.x% | |||
| 1 | 2 | 3 | 4 | Display zones | Specification | Evaluation |
| Intake air temperature correction factor | 7 to -15% | --- | ||||
| --- | ||||||
| Fuel correction factor | 0 to -27% | --- | ||||
| Engine speed (idling speed) Manual transmission Automatic transmission | 700 to 6800 RPM 640 to 6800 RPM | --- | ||||