Home >> Volkswagen >> 2001 >> Golf GL, 2.0 B >> Repair and Diagnosis >> External Pages >> Different car >> Section 78 (2.8L - Engine Mechanical - AFP (A4 Platform)) >> 20 - Fuel supply >> Evaporative emissions (EVAP) system >> Evaporative emissions system, leak testing >> Functional test

Functional test

WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2002 Volkswagen Jetta, 2002 Volkswagen GTI, 2001 Volkswagen Jetta, 2001 Volkswagen GTI, and 2000 Volkswagen Jetta. However, it is still accessible from the selected car via links, so may be relevant.

Indicated on display:

Rapid Data Transfer HELP
Select Function XX

Indicated on display:

Read Measuring Value Block
Enter Display Group No. XXX

Indicated on display

Read Measuring Value Block 71 ->
Reed closed Abort Test OFF

or

Indicated on display

Read Measuring Value Block 71 ->
Reed closed Messg.END Syst. OK
  Display Fields
  1 2 3 4
Display Group 71: Diagnosis of evaporative emissions system (leak testing)
Display Reed open Reed closed Fine leak/large leak Stop Syst. Test measurement end of measurement test OFF/test ON Syst. OK Syst. nOK
Indicator Reed-contact status Error message System status status of diagnosis and result
Working range --- --- --- ---
Specification Reed closed --- END of measurement System OK

If "reed open" appears in field 1:

If the specification is attained:

Indicated on display (1-4 = display fields).

System in basic setting 71 ->
1 2 3 4

If "reed open" appears in field 1:

If diagnosis is started by engine control module, display in field 4 will jump from "Test OFF" to "Test ON".

  Display fields
  1 2 3 4
Display Group 71: Diagnosis of evaporative emissions system (leak testing)
Display Reed open Reed closed   Syst. Test Measurement End of measurement Test OFF/test ON Syst. OK Syst. nOK
Indicator Status of reed contact   System status Status of diagnosis and Result
Working range ---   --- ---
Specifications Reed closed   END of measurement System. OK
NOTE:
  • If field 4 switches from "Test ON" to "Test OFF" during the diagnosis, repeat the leak testing.
  • The fuel tank cap must be opened briefly before the diagnosis can be repeated.

If the indicator does not behave as described:

If the specifications were attained:

If the specifications were not attained:

Indicated on display

Read Measuring Value Block 71 ->
Reed open Messg. END Syst. OK

Indicated on display (1-4 = display fields)

Read Measuring Value Block 70 ->
1 2 3 4
NOTE:
  • No load may be produced during this diagnosis. Otherwise the diagnosis will be stopped and can only be started again after applying the accelerator.

Indicated on display (1-4 = display fields)

System in Default70 ->
1 2 3 4

If diagnosis is started by ending control module, display in field 4 will jump from "Test OFF" to "Test ON".

NOTE:
  • If the display jumps from "Test ON" to "Test OFF" during the test, the test can be repeated by a short application of the accelerator.
  Display Fields
  1 2 3 4
Display Group 70: Diagnosis of evaporative emissions system (leak testing)
Display xxx % xx.x % xx.x g/s Test OFF/test ON TEV OK TEV nOK
Indicator Solenoid valve opens during diagnosis Deviation of A/F control during diagnosis Idle deviation during diagnosis status of diagnosis and result
Working Range 0-100 % -25.0-25.0 % -2.7-2.8 g/s ---
Specification --- --- --- TEV OK

If "TEV nOK" is displayed in field 4:

If the specification "TEV OK" was achieved: