Secondary air injection solenoid valve, checking
WARNING: This page is about a different variant/trim than selected.
Engine code AEG
Special tools and equipment
- V.A.G 1594 Adapter set
- V.A.G 15927 Diode test light
Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations
Requirements
- Coolant temperature 5 ° to 33 ° C
- Secondary air injection pump motor OK
Work sequence
- Pull upper vacuum hose (arrow) off secondary air injection solenoid valve.
- Start engine and run at idling speed.
When secondary air injection pump motor runs a vacuum must be perceptible at secondary air injection solenoid valve union.
If no vacuum is perceptible:
- Switch engine off.
- Disconnect 2-pin connector from secondary air injection solenoid valve (arrow).
- Connect voltage tester V.A.G 1527B to the outer contacts of connector with auxiliary cables from V.A.G 1594C.
- Start engine and run at idling speed.
LED must light up
LED lights up (voltage supply OK.):
- Replace secondary air injection solenoid valve.
If LED does not light up:
- Connect 2-pin connector
- Check activation of valve. Refer to Adapting components and functions , Adapting functions and components.
- Check wiring:
Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations
- Read DTC memory. Refer to Engine control module Diagnostic Trouble Code (DTC) memory, interrogating and erasing
- Read readiness code: Refer to Adapting components and functions , Adapting components and functions.
- Generate readiness code again if DTC memory has been erased or engine control module was disconnected from permanent positive. Refer to Adapting components and functions , Adapting components and functions.