Battery charger, connecting
WARNING: This page is about a different variant/trim than selected.
CAUTION:
Danger of explosion!
- Batteries produce explosive gasses while being charged.
- Keep open flames and sparks away and DO NOT smoke near batteries.
- The battery charger MUST be turned off when connecting or disconnecting the cables at the battery.
- Battery cell caps must NOT be removed while charging.
- "Boosting" a sulfated battery a high charging rate can cause an explosion.
- Ensure that battery is charged in a well ventilated area.
- Precision tools must not be kept in the same room where batteries are being charged. Tools may corrode due to chemical reaction.
Special tools, testers and auxiliary items required
- Midtronics Inc-940 Batt. Charg. Stn. INC-940.
NOTE:
- Before charging, battery must have a minimum temperature of 10 degrees Celsius (50 degrees Fahrenheit).
- It is not necessary to remove battery from vehicle or disconnect battery terminals.
- Charging voltage must not exceed 14.4V.
- Always follow the battery charger operating instructions.
- After charging, confirm battery no load voltage and electrolyte specific gravity before reuse in vehicle.
CAUTION:
Before beginning repairs on electrical system
- Switch off all electrical consumers.
- Switch ignition off and remove ignition key.
CAUTION:
If battery begins gassing (boiling) violently when charging, REDUCE charging rate immediately.
- Connect battery charger to battery, positive to positive ( + ), negative to negative ( - ).
- Switch on battery charger.
- Adjust charging rate according to battery capacity (refer to charger instructions).