LEMON Manuals: Even more car manuals for everyone
Home >> Volkswagen >> 1999 >> Golf Wolfsburg Edition, Automatic >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 18 (Electrical Equipment (A4 Platform)) >> 27 Battery, Starter, Generator, Cruise control >> Battery, checking >> Batteries without charge indicator (magic eye), checking >> Electrolyte level too low

Electrolyte level too low

WARNING: This page is about a different variant/trim than selected.
NOTE:

Design of filler support on filling bottle VAS 5045 prevents overfilling of battery cells and subsequent electrolyte leaks. When max. level is reached the flow of distilled water into battery cells stops. 

Fig 1: VAS 5045 Battery Filling Bottle
GW00004080Courtesy of VOLKSWAGEN UNITED STATES, INC.
CAUTION:
  • Only use distilled water to top-up batteries. This prevents electrolyte impurities which cause self-discharging.
  • DO NOT overfill the battery
  • Overfilled batteries can boil over.
  • Too little electrolyte reduces the service life of the battery.
  • Use of genuine VW battery cell caps ensures the different battery cover systems are sealed correctly. Only use genuine cell caps of the same construction if lost or damaged. All cell caps must be equipped with an O-ring seal.
NOTE: If it becomes necessary to top up the battery with distilled water, always perform battery test afterwards. Refer to Battery, testing  .