Multi-function Indicator (MFI) fuel consumption indicator, adaptation
WARNING: This page is about a different variant/trim than selected.
NOTE:
- Consumption indicator can only be adapted once between 85% and 115%.
- Value must be entered in steps of 5%.
- Connect scan tool VAG 1551, select operating mode 1 "Rapid data transfer", switch on ignition and enter address word 17 "instrument cluster".
- Press -Q- button to confirm input.
- Press → button until "Select function" appears in display.
Indicated on display:
| Rapid data transfer HELP Select function XX |
- Press buttons -1- and -0- to select "Adaptation" function 10.
Indicated on display:
| Rapid data transfer Q 10 - Adaptation |
- Press -Q- button to confirm input.
Indicated on display:
| Adaptation Enter channel number XX |
- Press buttons -0- and -3- to select adaptation "channel 03".
- Press -Q- button to confirm input.
Indicated on display:
| Channel 03 Adaptation 100 → < - 1 3- > |
- Press → button to continue.
NOTE:
Correction of fuel consumption display is only possible via direct input.
Indicated on display:
| Channel 03 Adaptation 100 Enter adaptation value XXXXX |
- Input desired correction value using scan tool button pad, filling initial positions with "0".
Example:
Desired input value: 90% = button pad entry: 00090
Indicated on display:
| Channel 03 Adaptation 100 Q Enter adaptation value 00090 |
- Press -Q- button to confirm input.
Indicated on display:
| Channel 03 Adaptation 90 Q < - 1 3- > |
- Press -Q- button to confirm input.
Indicated on display:
| Channel 03 Adaptation 90 Q Store changed value? |
- Press -Q- button to confirm input.
Indicated on display:
| Channel 03 Adaptation 90 → Changed value is stored |
- End consumption indicator adaptation with → button.
Indicated on display:
| Rapid data transfer HELP Select function XX |
NOTE:
A false entry switches the tester to "Select function" mode.
If the following display appears:
| Function is unknown or → cannot be carried out at the moment |
- Press → button.
- Select function "10 - Adaptation" and adaptation channel 03 again.
- Carry out corrections to consumption indicator and confirm with Q button.