LEMON Manuals: Even more car manuals for everyone
Home >> Volkswagen >> 1999 >> Golf Wolfsburg Edition, Automatic >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 12 (Brake System - OBD (A4 Platform)) >> 01 On Board Diagnostic (OBD) >> Electrical check of Mark 60 >> Test table (test steps 17 - 23)

Test table (test steps 17 - 23)

WARNING: This page is about a different variant/trim than selected.
Switch to measuring range: 
Voltage measurement (20 V =) in test step 17, resistance measurement (200 Ω )/(20 M Ω ) in test step 17a 
Test step  V.A.G 1598 sockets  Item tested 
  • Test conditions
  • Additional operations
Specification  Measures for deviations from specification 
17 - Voltage supply for steering angle sensor -G85-
  • Ignition switched off
  • Disconnect connection from steering angle sensor -G85-
   
     
  • Disconnect multi-pin connection T47 from ABS control module (w/EDL) -J104-
   
     
  • Check wiring between contact T6a/4 and contact T6a/1 of steering angle sensor -G85-
10.0 - 14.5 V
  • Check wiring using wiring diagram. Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations binder
17 - Voltage supply for steering angle sensor -G85-
  • Ignition switched on
  • Check wiring between contact T6a/5 and connector contact T6a/1 of steering angle sensor -G85-
10.0 - 14.5 V
  • Check wiring using wiring diagram. Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations binder
17a - Wiring for steering angle sensor -G85-
  • Measuring range set to 200 Ω
  • Ignition switched off
  • Connect test box V.A.G 1598/36
   
     
  • Check wiring for open circuit between steering angle sensor -G85- and ABS control module (w/EDL) -J104- multi-pin connector
Max. 1.5 Ω
  • Check wiring using wiring diagram. Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations binder
17a   Wiring for steering angle sensor -G85-
  • Set measuring range to 20 M Ω
  • Remove fuse S9
   
     
  • Check wiring for short circuit to positive or Ground
∞ Ω  
         
  • Check wiring using wiring diagram. Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations binder
Switch to measuring range: 
Resistance measurement (200 Ω /20 M Ω ) 
Test step  V.A.G 1598 sockets  Item tested 
  • Test conditions
  • Additional operations
Specification  Measures for deviations from specification 
18 - Wiring for sensor for transverse acceleration -G200- and sender for rotation rate -G202-
  • Ignition switched off
  • Measuring range set to 200 Ω
   
     
  • Connect test box V.A.G1598/36
   
     
  • Check wiring for open circuit between multi-pin connector of sensor for transverse acceleration -G200-, sender for rotation rate -G202- and multi-pin connector of ABS control module (w/EDL) -J104-:
Max. 1.5 Ω
  • Check wiring using wiring diagram. Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations binder
     
  • Set measuring range to 20 M Ω
  • Remove fuse S9
   
     
  • Check wiring for short circuit to positive or Ground
∞ Ω  
         
  • Check wiring using wiring diagram. Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations binder
Switch to measuring range: 
Resistance measurement (200 Ω /20 M Ω ) 
Test step  V.A.G 1598 sockets  Item tested 
  • Test conditions
  • Additional operations
Specification  Measures for deviations from specification 
19 - Wiring for sender 1 for brake booster -G201-
  • Ignition switched off
  • Measuring range set to 200 Ω
  • Disconnect connection from sender 1 for brake booster -G201-
  • Disconnect multi-pin connection T47 from ABS control module (w/EDL) -J104-
  • Connect test box V.A.G 1598/36
   
     
  • Check wiring for open circuit between sender 1 for brake booster -G201- multi-pin connector and ABS control module (w/EDL) -J104- multi-pin connector
Max. 1.5 Ω
  • Check wiring using wiring diagram. Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations binder
     
  • Set measuring range to 20 M Ω
  • Remove fuse S9
   
     
  • Check wiring for short circuit to positive or Ground
∞ Ω  
         
  • Check wiring using wiring diagram. Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations binder
Switch to measuring range: 
Resistance measurement (200 Ω /20 M Ω ) 
Test step  V.A.G 1598 sockets  Item tested 
  • Test conditions
  • Additional operations
Specification  Measures for deviations from specification 
20 11 or 15 Data bus wiring
  • Ignition switched off
  • Measuring set range to 200 Ω
  • Disconnect multi-pin connection from a control module which is connected via data bus wiring:
  • Connect test box V.A.G 1598/36
   
     
  • Check data bus wiring for open circuit
Max. 1.5 Ω
  • Check wiring using wiring diagram. Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations binder
     
  • Set measuring range to 20 M Ω
  • Remove fuse S9
   
     
  • Check wiring for short circuit to positive or Ground
∞ Ω  
         
  • Check wiring using wiring diagram. Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations binder
Switch to measuring range: 
Voltage measurement (20 V =) 
Test step  V.A.G 1598 sockets  Item tested 
  • Test conditions
  • Additional operations
Specification  Measures for deviations from specification 
21 - Voltage supply for V.A.G 1551, connector T161)
  • Ignition switched off
  • Connect hand multimeter V.A.G 1526 to connector T161) using adapter set V.A.G 1594
10.0 -14.5 V  
         
  • Check wiring using wiring diagram. Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations binder

1) Diagnosis connector contact assignment. Refer to Multi-pin connector with contact assignments 

Switch to measuring range: 
Resistance measurement 200 Ω 
Test step  V.A.G 1598 sockets  Item tested 
  • Test conditions
  • Additional operations
Specification  Measures for deviations from specification 
22 - Resistance of K wire for V.A.G 1551, connector T161)
  • Ignition switched off
  • Disconnect multi-pin connector from ABS control module (w/EDL) -J104
  • Connect test box V.A.G 1598/36
  • Connect hand multimeter V.A.G 1526 to contacts T16/71) and T47/2 of multi-pin connector of ABS control module (w/EDL) -J104- using cables from adapter set V.A.G 1594
Max. 1.5 Ω
  • Check wiring using wiring diagram. Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations binder

1) Diagnosis connector contact assignment. Refer to Multi-pin connector with contact assignments 

Switch to measuring range: 
Resistance measurement (200 Ω ) 
Test step  V.A.G 1598 sockets  Item tested 
  • Test conditions
  • Additional operations
Specification  Measures for deviations from specification 
23 14 + 38 Coding bridge for
ABS and
ABS/EDL/ASR
front wheel drive
  • Ignition switched off
0.0 -1.0 Ω  
  12 + 38 Coding bridge for
ABS/EDL/ASR/ESP front wheel drive
     
  12 + 9 Coding bridge for
ABS/EDL/ASR/ESP 4MOTION
     
         
  • Check wiring using wiring diagram. Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations binder