High Voltage Battery Management Diagnosis (01 Of 10)
- DTC P0A0A-01: HV Interlock Error - General Electric Failure
- DTC P0A7D-00: Minimum Pack State Of Charge Limit Critically Exceeded
- DTC P0AA1-73: Positive HV Contractor Stuck Closed - Actuator Stuck Closed
- DTC P0AA2-72: Positive HV Contractor Stuck Open - Actuator Stuck Open
- DTC P0AA4-73: Negative HV Contractor Stuck Closed - Actuator Stuck Closed
- DTC P0AA5-72: Negative HV Contractor Stuck Open - Actuator Stuck Open
- DTC P0AA6-1A: Isolation Error In Open Contractor State - Circuit Resistance Below Threshold
- DTC P0AA6-1E: Isolation Resistance Warning (Closed) - Circuit Resistance Out Of Range
- DTC P0AA9-1A: Isolation Error In Open Contractor State - Circuit Resistance Below Threshold
- DTC P0AA9-1E: Isolation Resistance Warning (Open) - Circuit Resistance Out Of Range
- DTC P0AAC-01: Coolant Inlet Temperature Sensor Electrical Error - General Electric Failure
- DTC P0AB1-01: Coolant Outlet Temperature Sensor Electrical Error - General Electric Failure
- DTC P0ABF-62: Current Sensor 1 Plausibility Check Error - Signal Compare Failure
- DTC P0AC2-19: Current Sensor Amperage Limit Exceeded - Circuit Current Above Threshold
- DTC P0ADA-01: Hybrid/EV Battery Positive Contactor Control Circuit Range/Performance - General Electric Failure
- DTC P0ADE-01: Hybrid/EV Battery Negative Contactor Control Circuit Range/Performance - General Electric Failure
- DTC P0AE2-73: Pre-Charge HV Contractor Stuck Closed - Actuator Stuck Closed
- DTC P0AE3-72: Pre-Charge HV Contractor Stuck Open - Actuator Stuck Open
- DTC P0AE5-01: Hybrid/EV Battery Pre-Charge Contactor "A" Control Circuit Range/Performance - General Electric Failure
- DTC P0AFA-16: Minimum Pack Voltage Limit Critically Exceeded - Circuit Voltage Below Threshold
- DTC P0AFB-17: Minimum Pack Voltage Limit Critically Exceeded - Circuit Voltage Above Thresholds
- DTC P1200-01: Maximum Pre-Charge Duration Exceeded - General Electric Failure
- DTC P1201-01: Maximum Main Connect Duration Exceeded - General Electric Failure
- DTC P1202-01: Maximum Shutoff Duration Exceeded - General Electric Failure
- DTC P1203-01: Maximum Disconnect Duration Exceeded - General Electric Failure
- DTC P1204-01: Maximum Emergency Disconnect Duration Exceeded - General Electric Failure
- DTC P1205-01: Maximum Pre-Charge Current Limit Exceeded - General Electric Failure
- DTC P1206-01: Maximum Main Connect Current Limit Exceeded - General Electric Failure
- DTC U3002-55: Vehicle Identification Number - Not Configured
- DTC P120D-19: Maximum Service Mode Current Limit Exceeded - Circuit Current Above Threshold
- DTC P1214-4B: Pre-Charge Resistor Overheat Warning - Over Temperature
- DTC P1215-62: Pre-Charge Plausibility Check Maximum Voltage Exceeded - Signal Compare Failure
- DTC P1216-62: Pre-Charge Plausibility Check Minimum Voltage Exceeded - Signal Compare Failure
- DTC P1217-01: Pre-Charge Energy Limit Exceeded - General Electric Failure
- DTC P1218-19: Charge Current Limit Critically Exceeded - Circuit Current Above Threshold
- DTC P1219-19: Discharge Current Limit Critically Exceeded - Circuit Current Above Threshold
- DTC P121A-19: Charge Current Limit Exceeded (Warning) - Circuit Current Above Threshold
- DTC P121B-19: Discharge Current Limit Exceeded (Warning) - Circuit Current Above Threshold
- DTC P121D-17: Maximum Cell Voltage Limit Critically Exceeded - Circuit Voltage Above Threshold
- DTC P121E-16: Minimum Cell Voltage Limit Critically Exceeded - Circuit Voltage Below Threshold
- DTC P1225-62: Voltage Acquisition 1 Plausibility Check Error - Signal Compare Failure
- DTC P1226-62: Voltage Acquisition 2 Plausibility Check Error - Signal Compare Failure
- DTC P1227-62: Voltage Acquisition 3 Plausibility Check Error - Signal Compare Failure
- DTC P1228-62: Voltage Acquisition 5 Plausibility Check Error - Signal Compare Failure
- DTC P1229-62: Module Voltage Acquisition Plausibility Check Error - Signal Compare Failure
- DTC P122A-62: Cell Voltage Acquisition Plausibility Check Error - Signal Compare Failure
- DTC P122B-62: Load Circuit Voltage Acquisition Plausibility Check Error - Signal Compare Failure
- DTC P122C-1E: Maximum Pack Resistance Limit Exceeded - Circuit Resistance Out Of Range
- DTC P122E-62: Current Sensor 2 Plausibility Check Error - Signal Compare Failure
- DTC P122F-01: Load Circuit Voltage Did Not Decrease In Time For Contractor Diagnosis - General Electric Failure