High Voltage Battery Management Diagnosis (4 Of 10)
- DTC P12A4-06: SOC Initialization Error Of Module 04 - Algorithm Based Failures
- DTC P12A4-62: Large Difference Between Predicted And Measured Voltage Of Module 04 - Signal Compare Failure
- DTC P12A4-91: Large Capacitance Change Of Module 4
- DTC P12A4-92: Critical Electrical Status Of The Cell Temperature Sensors In Module #4 - Performance Or Incorrect Operation
- DTC P12A5-00: Electrical Status Of The Cell Temperature Sensors In Module #5
- DTC P12A5-01: Low Cell SOC Module 05 - General Electric Failure
- DTC P12A5-06: SOC Initialization Error Of Module 05 - Algorithm Based Failures
- DTC P12A5-09: MCU Error Of Device 5 - Component Failure
- DTC P12A5-1B: High Cell Resistance Module 5 - Circuit Resistance Above Threshold
- DTC P12A5-1E: Large Resistance Change Of Module 5 - Circuit Resistance Out Of Range
- DTC P12A5-1F: Plausibility Error Of Temperature Sensors In Module 5 - Circuit Intermittent
- DTC P12A5-49: Electrical Status Of The Module Controller Temperature Sensor 5 - Internal Electronic Failure
- DTC P12A5-62: Large Difference Between Predicted And Measured Voltage Of Module 05 - Signal Compare Failure
- DTC P12A5-91: Large Capacitance Change Of Module 5 - Parametric
- DTC P12A5-92: Critical Electrical Status Of The Cell Temperature Sensors In Module 5 - Performance Or Incorrect Operation
- DTC P12A6-00: Electrical Status Of The Cell Temperature Sensors In Module 6
- DTC P12A6-01: Low Cell SOC Module 06 - General Electric Failure
- DTC P12A6-06: SOC Initialization Error Of Module 06 - Algorithm Based Failures
- DTC P12A6-09: MCU Error Of Device 6 - Component Failure
- DTC P12A6-1B: High Cell Resistance Module 6 - Circuit Resistance Above Threshold
- DTC P12A6-1E: Large Resistance Change Of Module 6 - Circuit Resistance Out Of Range
- DTC P12A6-1F: Plausibility Error Of Temperature Sensors In Module 6 - Circuit Intermittent
- DTC P12A6-49: Electrical Status Of The Module Controller Temperature Sensor #6 - Internal Electronic Failure
- DTC P12A6-62: Large Difference Between Predicted And Measured Voltage Of Module 06 - Signal Compare Failure
- DTC P12A6-91: Large Capacitance Change Of Module 06 - Parametric
- DTC P12A6-92: Critical Electrical Status Of The Cell Temperature Sensors In Module 6 - Performance Or Incorrect Operation
- DTC P12A7-00: Electrical Status Of The Cell Temperature Sensors In Module 7
- DTC P12A7-01: Low Cell SOC Module 07 - General Electric Failure
- DTC P12A7-06: SOC Initialization Error Of Module 07 - Algorithm Based Failures
- DTC P12A7-09: MCU Error Of Device 7 - Component Failure
- DTC P12A7-1B: High Cell Resistance Module 07 - Circuit Resistance Above Threshold
- DTC P12A7-1E: Large Resistance Change Of Module 07 - Circuit Resistance Out Of Range
- DTC P12A7-1F: Plausibility Error Of Temperature Sensors In Module 7 - Circuit Intermittent
- DTC P12A7-49: Electrical Status Of The Module Controller Temperature Sensor 7 - Internal Electronic Failure
- DTC P12A7-62: Large Difference Between Predicted And Measured Voltage Of Module 07 - Signal Compare Failure
- DTC P12A7-91: Large Capacitance Change Of Module 07 - Parametric
- DTC P12A7-92: Critical Electrical Status Of The Cell Temperature Sensors In Module 7 - Performance Or Incorrect Operation
- DTC P12A8-00: Electrical Status Of The Cell Temperature Sensors In Module 8
- DTC P12A8-01: Low Cell SOC Module 08 - General Electric Failure
- DTC P12A8-06: SOC Initialization Error Of Module 08
- DTC P12A8-09: MCU Error Of Device 8 - Component Failure
- DTC P12A8-1B: High Cell Resistance Module 08 - Circuit Resistance Above Threshold
- DTC P12A8-1E: Large Resistance Change Of Module 08 - Circuit Resistance Out Of Range
- DTC P12A8-1F: Plausibility Error Of Temperature Sensors In Module #8 - Circuit Intermittent
- DTC P12A8-49: Electrical Status Of The Module Controller Temperature Sensor #8 - Internal Electronic Failure
- DTC P12A8-62: Large Difference Between Predicted And Measured Voltage Of Module 08 - Signal Compare Failure
- DTC P12A8-91: Large Capacitance Change Of Module 08 - Parametric
- DTC P12A8-92: Critical Electrical Status Of The Cell Temperature Sensors In Module #8-Performance Or Incorrect Operation
- DTC P12A9-00: Electrical Status Of The Cell Temperature Sensors In Module #9
- DTC P12A9-01: Low Cell SOC Module 09 - General Electric Failure
- DTC P12A9-06: SOC Initialization Error Of Module 09 - Algorithm Based Failures