DTC B1500-13: Fuel Sender Circuit Open [10/2022 - ]: Procedure
- INSPECT FUEL SENDER GAUGE ASSEMBLY
Refer to INSPECTION [06/2020 - ]
Result
Proceed to OK NG Result:
NG
REPLACE FUEL SENDER GAUGE ASSEMBLY. Refer to REMOVAL [10/2022 - ]
Result:
OK
See step 2
- INSPECT FUEL SUCTION WITH PUMP AND GAUGE TUBE ASSEMBLY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A-1 (FV) - B-1 Always Below 1 Ω A-2 (FE) - B-2 Always Below 1 Ω A-3 (FS) - B-3 Always Below 1 Ω Result
Proceed to OK NG
Result:
NG
REPLACE FUEL SUCTION WITH PUMP AND GAUGE TUBE ASSEMBLY. Refer to REMOVAL [10/2022 - ]
Result:
OK
See step 3
- Measure the resistance according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (FUEL SUCTION WITH PUMP AND GAUGE TUBE ASSEMBLY - COMBINATION METER ASSEMBLY)
- Disconnect the N47 fuel suction with pump and gauge tube assembly connector.
- Disconnect the G18*1 or G184*2 combination meter assembly connector.
- *1: for 7 Inch Multi-information Display Type
- *2: for 12.3 Inch Multi-information Display Type
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
FOR 7 INCH MULTI-INFORMATION DISPLAY TYPETester Connection Condition Specified Condition N47-3 (FS) - G18-31 (FR) Always Below 1 Ω N47-2 (FE) - G18-24 (FE&B) Always Below 1 Ω N47-1 (FV) - G18-14 (FV) Always Below 1 Ω N47-3 (FS) or G18-31 (FR) - Other terminals and body ground Always 10 kΩ or higher N47-2 (FE) or G18-24 (FE&B) - Other terminals and body ground Always 10 kΩ or higher N47-1 (FV) or G18-14 (FV) - Other terminals and body ground Always 10 kΩ or higher FOR 12.3 INCH MULTI-INFORMATION DISPLAY TYPETester Connection Condition Specified Condition N47-3 (FS) - G184-7 (FR) Always Below 1 Ω N47-2 (FE) - G184-25 (FE&B) Always Below 1 Ω N47-1 (FV) - G184-23 (FV) Always Below 1 Ω N47-3 (FS) or G184-7 (FR) - Other terminals and body ground Always 10 kΩ or higher N47-2 (FE) or G184-25 (FE&B) - Other terminals and body ground Always 10 kΩ or higher N47-1 (FV) or G184-23 (FV) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [10/2022 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR