Shift Control ECU Communication Stop Mode [12/2022 - ]: Procedure
- CHECK FOR OPEN IN CAN BUS LINES (TRANSMISSION FLOOR SHIFT ASSEMBLY BRANCH LINE)
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- Disconnect the K53 transmission floor shift assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition K53-15 (CA1H) - K53-16 (CA1L) Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE CAN BRANCH LINES OR CONNECTOR (TRANSMISSION FLOOR SHIFT ASSEMBLY)
Result:
OK
See step 2
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition K53-23 (E12) - Body ground Cable disconnected from negative (-) auxiliary battery terminal Below 1 Ω K53-9 (E1) - Body ground Cable disconnected from negative (-) auxiliary battery terminal Below 1 Ω - Reconnect the cable to the negative (-) auxiliary battery terminal.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition K53-1 (IGP) - Body ground Ignition switch ON 11 to 14 V K53-2 (BATT) - Body ground Ignition switch off 11 to 14 V K53-3 (IGCT) - Body ground Ignition switch ON 11 to 14 V Result
Proceed to OK NG
Result:
OK
REPLACE TRANSMISSION FLOOR SHIFT ASSEMBLY
Refer to REMOVAL [12/2022 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.