LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2025 >> Prius Plug-In Hybrid SE >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 6 (Hybrid Control System (HEV) - Diagnostic Codes (1 Of 4)) >> HYBRID CONTROL SYSTEM (for M20A-FXS) >> DTC P0AA3-73: Hybrid/EV Battery Negative Contactor Actuator Stuck Closed [12/2022 - ] >> Caution / Notice / Hint

Caution / Notice / Hint

WARNING: This page is about a different variant/trim than selected.
WARNING:

Refer to the precautions before inspecting high voltage circuit.

Refer to PRECAUTION [12/2022 - ]

NOTE:
  • If the DTCs are cleared or the cable is disconnected and reconnected to the negative (-) auxiliary battery terminal before performing repairs, turning the ignition switch to ON (READY) may cause a malfunction. Do not turn the ignition switch to ON (READY).
  • After the ignition switch is turned off, there may be a waiting time before disconnecting the negative (-) auxiliary battery terminal.

    Refer to BEFORE DISCONNECTING BATTERY [12/2022 - ]

  • When disconnecting and reconnecting the auxiliary battery

    HINT: 

    When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

    Refer to AUTOMATIC LEARNING CHART [12/2022 - 03/2023] , or refer to AUTOMATIC LEARNING CHART [03/2023 - ]

HINT: 

Malfunction Content System Relevant DTC
Microcomputer malfunction Hybrid control system P0606-47 Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure
P0606-87 Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message
P060A-47 Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure
P060A-87 Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message
P0A1B-49 Drive Motor "A" Control Module Internal Electronic Failure
P1C9E-9F Hybrid/EV System Reset Stuck Off
P060B-49 Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure
Motor generator control system P0A1B-1F Generator Control Module Circuit Intermittent
P0A1A-47 Generator Control Module Watchdog / Safety μC Failure
P0A1A-49 Generator Control Module Internal Electronic Failure
P1C2A-1C Generator A/D Converter Circuit Circuit Voltage Out of Range
P1C2A-49 Generator A/D Converter Circuit Internal Electronic Failure
P1C2B-1C Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range
P1C2B-49 Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure
P1CAC-49 Generator Position Sensor Internal Electronic Failure
P1CAD-49 Drive Motor "A" Position Sensor Internal Electronic Failure
P1CAF-38 Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect
P1CB0-38 Drive Motor "A" Position Sensor REF Signal Frequency Incorrect
P3133-83 Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect
P3133-86 Communication Error from Generator to Drive Motor "A" Signal Invalid
Hybrid battery system P060B-49 Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure
P0606-87 Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message
P060A-47 Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure
P060A-87 Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message
P0E2D-00 Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance
Power source circuit malfunction Motor generator control system P06D6-1C Generator Control Module Offset Power Circuit Voltage Out of Range
P06B0-1C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
Communication system malfunction Hybrid control system U0111-87 Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message
Motor generator control system P3133-87 Communication Error from Generator to Drive Motor "A" Missing Message
Sensor and actuator circuit malfunction Hybrid control system P0AD9-11 Hybrid/EV Battery Positive Contactor Circuit Short to Ground
P0AD9-15 Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open
P0ADD-11 Hybrid/EV Battery Negative Contactor Circuit Short to Ground
P0ADD-15 Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open
Motor generator control system P0A3F-16 Drive Motor "A" Position Sensor Circuit Voltage Below Threshold
P0A4B-16 Generator Position Sensor Circuit Voltage Below Threshold
P0A4B-21 Generator Position Sensor Signal Amplitude < Minimum
P0A4B-22 Generator Position Sensor Signal Amplitude > Maximum
P0C50-13 Drive Motor "A" Position Sensor Circuit "A" Circuit Open
P0C50-16 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C50-17 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C5A-13 Drive Motor "A" Position Sensor Circuit "B" Circuit Open
P0C5A-16 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C5A-17 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold
P0C64-13 Generator Position Sensor Circuit "A" Circuit Open
P0C64-16 Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C64-17 Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C69-13 Generator Position Sensor Circuit "B" Circuit Open
P0C69-16 Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C69-17 Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold
Hybrid battery system P301A-1C Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range
P1A00-1C Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range
P1AFD-1C Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range
System malfunction Hybrid control system P0C76-00 Hybrid/EV Battery System Discharge Time Too Long
P0D2D-1C Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range
P1C83-49 High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction
Motor generator control system P0D2D-16 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold
P0D2D-17 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold
P1CB6-9E Drive Motor "A" Inverter Voltage Sensor (VH) Stuck On