Motor Generator Control ECU Communication Stop Mode [12/2022 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- Disconnect the A88 inverter with converter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A88-4 (GND1) - Body ground Cable disconnected from negative (-) auxiliary battery terminal Below 1 Ω A88-12 (GND2) - Body ground Cable disconnected from negative (-) auxiliary battery terminal Below 1 Ω - Reconnect the cable to the negative (-) auxiliary battery terminal.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition A88-1 (IGC1) - Body ground Ignition switch ON 11 to 14 V A88-9 (IGC2) - Body ground Ignition switch ON 11 to 14 V Result
Proceed to OK NG
Result:
OK
REPLACE INVERTER WITH CONVERTER ASSEMBLY
Refer to REMOVAL [12/2022 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER SOURCE CIRCUIT)