Inspection [12/2022 - ]: Procedure
- INSPECT POWER BACK DOOR CONTROL SWITCH
- Check the switch.
*a Component without harness connected
(Power Back Door Control Switch)- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result K65-5 (CSW) - K65-2 (E) Pushed (ON) Below 1 Ω Ω K65-5 (CSW) - K65-2 (E) Not Pushed (OFF) 10 kΩ or higher kΩ If the result is not as specified, replace the power back door control switch.
- Measure the resistance according to the value(s) in the table below.
- Check the switch illumination.
- Apply auxiliary battery voltage to the switch connector and check that the power back door control switch illuminates.
OK
Tester Connection Condition Specified Condition Auxiliary battery positive (+) → Terminal K65-6 (ILL+)
Auxiliary battery negative (-) → Terminal K65-1 (ILL-)Always Switch illumination illuminates If the result is not as specified, replace the power back door control switch.
- Apply auxiliary battery voltage to the switch connector and check that the power back door control switch illuminates.
- Check the switch.