Inspection [02/2024 - ]: Procedure
- INSPECT BLOWER CONTROL SWITCH ASSEMBLY
- Check the blower control switch assembly.
*a Component without harness connected
(Blower Control Switch Assembly)- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition q6-5 (+B) - q6-2 (E) Pushed (ON) Below 1 Ω q6-5 (+B) - q6-2 (E) Not pushed (OFF) 10 kΩ or higher If the result is not as specified, replace the rear console box sub-assembly.
- Measure the resistance according to the value(s) in the table below.
*a Illumination *b Component without harness connected
(Blower Control Switch Assembly)Check the illumination.
*a Indicator *b Component without harness connected
(Blower Control Switch Assembly)Check the indicator.
- Check the blower control switch assembly.
- INSPECT COOL BOX BLOWER MOTOR WITH FAN SUB-ASSEMBLY
- Check the operation of the cool box blower motor with fan sub-assembly.
*a Component without harness connected
(Cool Box Blower Motor With Fan Sub-assembly)- Apply battery voltage to the rear blower motor with fan sub-assembly terminals.
OK
Tester Connection Condition Specified Condition q5-1 - Battery positive (+)
q5-2 - Battery negative (-)Always Operates smoothly If the result is not as specified, replace the cool box blower motor with fan sub-assembly.
- Apply battery voltage to the rear blower motor with fan sub-assembly terminals.
- Check the operation of the cool box blower motor with fan sub-assembly.
- INSPECT COOLER MAGNET VALVE ASSEMBLY
- Apply battery voltage to the terminals of the connector, and check the cooler magnet valve assembly operates.
OK
Tester Connection Specified Condition q7-1 - Battery positive (+)
q7-2 - Battery negative (-)Magnet valve is engaged If the result is not as specified, replace the cooler magnet valve assembly.
*a Component without harness connected
(Cooler Magnet Valve Assembly)
- Apply battery voltage to the terminals of the connector, and check the cooler magnet valve assembly operates.