Removal [12/2022 - 03/2023]: Procedure
- RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
- for HFC-134a (R134a):
Refer to PROCEDURE - Step 1
- for HFO-1234yf (R1234yf):
Refer to PROCEDURE - Step 1
- for HFC-134a (R134a):
- REMOVE SERVICE PLUG GRIP
Refer to REMOVAL [12/2022 - ]
- CHECK TERMINAL VOLTAGE
Refer to PROCEDURE - Step 13 - REMOVE RADIATOR SUPPORT OPENING COVER
Refer to PROCEDURE - Step 3
- REMOVE INLET NO. 1 AIR CLEANER
Refer to PROCEDURE - Step 4
- REMOVE NO. 1 ENGINE UNDER COVER ASSEMBLY
Refer to PROCEDURE - Step 10
- DISCONNECT SUCTION HOSE SUB-ASSEMBLY
- DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY
- REMOVE COMPRESSOR WITH MOTOR ASSEMBLY
*a Connector (A) *b Connector (B) *c Green-colored Lock - - Slide - - - Slide the green-colored lock of the connector (A) as shown in the illustration to release it and disconnect the connector.WARNING:
Make sure to wear insulated gloves.
NOTE:Insulate the disconnected terminals and connector (A) with insulating tape.
- Disconnect the connector (B).
- Slide the green-colored lock of the connector (A) as shown in the illustration to release it and disconnect the connector.
- Remove the 4 bolts and compressor with motor assembly.