DTC P2530-14: Ignition Switch Run Position Circuit Short to Ground or Open [02/2024 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (IG2 TERMINAL)
Procedure1
- Make sure that there is no looseness at the locking part and the connecting part of the connector.
OK
The connector is securely connected.
Pre-procedure1
- Disconnect the A49 No. 2 skid control ECU (brake actuator assembly) connector.
Procedure2
- Check both the connector case and the terminals for deformation and corrosion.
OK
No deformation or corrosion.
Pre-procedure2
- Turn the ignition switch to ON.
Procedure3
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition A49-15 (IG2) - Body ground Ignition switch ON 11 to 14 V Result
Proceed to OK NG Post-procedure1
- None
Result:
OK
REPLACE BRAKE ACTUATOR ASSEMBLY
Refer to REMOVAL [02/2024 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- Make sure that there is no looseness at the locking part and the connecting part of the connector.