Inspection [02/2024 - ]: Procedure
- INSPECT FUEL LID OPENER SWITCH
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Fuel Lid Opener Switch)Standard Resistance
Tester Connection Switch Condition Specified Condition E93-5 (IG) - E93-2 (E) Pushed (ON) Below 1 Ω E93-5 (IG) - E93-2 (E) Not pushed (OFF) 10 kΩ or higher If the result is not as specified, replace the fuel lid opener switch.
- Check that the switch illuminates.
- Apply auxiliary battery voltage to the fuel lid opener switch and check that the switch illuminates.
OK
Tester Connection Specified Condition Auxiliary battery positive (+) → E93-6 (ILL+)
Auxiliary battery negative (-) → E93-1 (ILL-)Illumination illuminates If the result is not as specified, replace the fuel lid opener switch.
- Apply auxiliary battery voltage to the fuel lid opener switch and check that the switch illuminates.
- Measure the resistance according to the value(s) in the table below.