Power Source Circuit [02/2024 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (STEREO COMPONENT EQUALIZER ASSEMBLY - AUXILIARY BATTERY [+B, IGP] AND BODY GROUND)
- Disconnect the stereo component equalizer assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition L38-15 (+B) - Body ground Ignition switch off 11 to 14 V L38-29 (IGP) - Body ground Ignition switch ON 11 to 14 V - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition L38-30 (GND) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [02/2024 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR