Operating Light Control Rheostat does not Change Light Brightness [02/2024 - ]: Procedure
- READ VALUE USING GTS (Light Control Switch (UP), Light Control Switch (DOWN))
- Using the GTS, read the Data List.
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Light Control Switch (UP) Light control rheostat up switch (Trip switch) OFF or ON OFF: Switch released
ON: Switch pushed- Light Control Switch (DOWN) Light control rheostat down switch (Trip switch) OFF or ON OFF: Switch released
ON: Switch pushed- Body Electrical > Combination Meter > Data List
Tester Display Light Control Switch (UP) Light Control Switch (DOWN) OK
Light control rheostat condition displayed on the GTS changes with the actual switch operation.
Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY
Refer to REMOVAL [02/2024 - ]
Result:
NG
See step 2
- Using the GTS, read the Data List.
- INSPECT LIGHT CONTROL RHEOSTAT
Refer to INSPECTION [02/2024 - ]
Result
Proceed to OK NG Result:
NG
REPLACE LIGHT CONTROL RHEOSTAT
Refer to REMOVAL [02/2024 - ]
Result:
OK
See step 3
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - LIGHT CONTROL RHEOSTAT)
- Disconnect the E7*1, E8*1 or E5*2 combination meter assembly connector.
- *1: for 7 Inch Multi-information Display Type
- *2: for 12.3 Inch Multi-information Display Type
- Disconnect the E74 light control rheostat connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
FOR 7 INCH MULTI-INFORMATION DISPLAY TYPETester Connection Condition Specified Condition E8-25 (SW) - E74-5 (T) Always Below 1 Ω E8-26 (TC) - E74-3 (TC) Always Below 1 Ω E8-27 (SW2) - E74-4 (RV) Always Below 1 Ω E7-36 (SW3) - E74-2 (E) Always Below 1 Ω E8-25 (SW) or E74-5 (T) - Body ground Always 10 kΩ or higher E8-26 (TC) or E74-3 (TC) - Body ground Always 10 kΩ or higher E8-27 (SW2) or E74-4 (RV) - Body ground Always 10 kΩ or higher E7-36 (SW3) or E74-2 (E) - Body ground Always 10 kΩ or higher FOR 12.3 INCH MULTI-INFORMATION DISPLAY TYPETester Connection Condition Specified Condition E5-11 (SW) - E74-5 (T) Always Below 1 Ω E5-10 (TC) - E74-3 (TC) Always Below 1 Ω E5-28 (SW2) - E74-4 (RV) Always Below 1 Ω E5-26 (SW3) - E74-2 (E) Always Below 1 Ω E5-11 (SW) or E74-5 (T) - Body ground Always 10 kΩ or higher E5-10 (TC) or E74-3 (TC) - Body ground Always 10 kΩ or higher E5-28 (SW2) or E74-4 (RV) - Body ground Always 10 kΩ or higher E5-26 (SW3) or E74-2 (E) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY
Refer to REMOVAL [02/2024 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- Disconnect the E7*1, E8*1 or E5*2 combination meter assembly connector.