No Warm Air Comes Out [01/2019 - 09/2022]: Procedure
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Powertrain / Engine / Data List.
- Read the Data List according to the display on the Techstream.
Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Coolant Temperature Engine coolant temperature Min.: -40°C (-40°F), Max.: 140°C (284°F) 75 to 100°C (167 to 212°F): After warming up This is the engine coolant temperature. HINT:
- After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).
- After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.
- If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.
- Check if the engine overheats if the value indicated is higher than 135°C (275°F).
Powertrain > Engine > Data List
Tester Display Coolant Temperature OK
After warming up the engine, the temperature value displayed is within the range specified in the normal condition column.
Result
Proceed to OK NG
Result:
NG
GO TO COOLING SYSTEM. Refer to ON-VEHICLE INSPECTION [01/2019 - 04/2020] , or refer to ON-VEHICLE INSPECTION [04/2020 - ]
Result:
OK
See step 2
- PERFORM ACTIVE TEST USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Active Test.
- Perform the Active Test according to the display on the Techstream.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383Operates between 165 and 257 pulses Body Electrical > Air Conditioner > Active Test
Tester Display Air Mix Servo Targ Pulse(D) OK
The No. 1 air conditioning radiator damper servo motor operates.
Result
Proceed to OK NG
Result:
NG
GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR. Refer to DIAGNOSTIC TROUBLE CODE CHART [01/2019 - 04/2020] , or refer to DIAGNOSTIC TROUBLE CODE CHART [04/2020 - 09/2022]
Result:
OK
See step 3
- CONFIRM MODEL
Result:
B
REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY. Refer to DISASSEMBLY [01/2019 - 06/2020] , or refer to DISASSEMBLY [06/2020 - 09/2022]
Result:
A
See step 4
- PERFORM ACTIVE TEST USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Active Test / Heater Active Level / Data List / Electric Heater Active Level.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Heater Active Level Quick heater assembly Min.: 0
Max.: 3- Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Electric Heater Active Level Actual electric heater operation level Min.: 0
Max.: 3Actual operation level of electric heater displayed PTC heater circuit malfunction Body Electrical > Air Conditioner > Active Test
Active Test Display Heater Active Level Data List Display Electric Heater Active Level - Check that the value of the Data List item Electric Heater Active Level changes in accordance with the set value of the Active Test item Heater Active Level.
OK
Techstream Operation Data List (Electric Heater Active Level) 0 to 3 0 to 3 Result
Proceed to OK NG
Result:
OK
REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY. Refer to DISASSEMBLY [01/2019 - 06/2020] , or refer to DISASSEMBLY [06/2020 - 09/2022]
Result:
NG
GO TO PTC HEATER CIRCUIT. Refer to PTC Heater Circuit [01/2019 - 09/2022]