Inspection [12/2022 - ]: Procedure
- INSPECT FUEL LID LOCK WITH MOTOR ASSEMBLY (for 2ZR-FXE)
- Check the operation of the fuel lid lock with motor assembly (motor operation).
- Apply auxiliary battery voltage to the fuel lid lock with motor assembly connector, and check the operation of the fuel lid lock with motor assembly.
Standard
Auxiliary Battery Connection Specified Condition Auxiliary battery positive (+) → Terminal R37-1 (B)
Auxiliary battery negative (-) → Terminal R37-2 (E)16.05 mm
(0.632 in.)If the result is not as specified, replace the fuel lid lock with motor assembly.
*a Component without harness connected
(Fuel Lid Lock with Motor Assembly)*b Shaft Stroke *c Lever *d Shaft
- Apply auxiliary battery voltage to the fuel lid lock with motor assembly connector, and check the operation of the fuel lid lock with motor assembly.
- Measure the shaft stroke.
Standard
Area Condition Specified Condition Shaft stroke Lever pulled 16.05 mm
(0.632 in.)If the result is not as specified, replace the fuel lid lock with motor assembly.
- Check the operation of the fuel lid lock with motor assembly (motor operation).
- INSPECT FUEL LID LOCK WITH MOTOR ASSEMBLY (for M20A-FXS)
- Check the operation of the fuel lid lock with motor assembly (motor operation).
- Apply auxiliary battery voltage to the fuel lid lock with motor assembly connector, and check the operation of the fuel lid lock with motor assembly.
Standard
Auxiliary Battery Connection Specified Condition Auxiliary battery positive (+) → Terminal R37-1 (B)
Auxiliary battery negative (-) → Terminal R37-2 (E)16.05 mm
(0.632 in.)If the result is not as specified, replace the fuel lid lock with motor assembly.
*a Component without harness connected
(Fuel Lid Lock with Motor Assembly)*b Shaft Stroke *c Lever *d Shaft
- Apply auxiliary battery voltage to the fuel lid lock with motor assembly connector, and check the operation of the fuel lid lock with motor assembly.
- Check the operation of the fuel lid lock with motor assembly (fuel lid courtesy switch).
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result R37-2 (E) - R37-3 (B) Shaft not pushed (ON) Below 1 Ω Ω R37-2 (E) - R37-3 (B) Shaft pushed (OFF) 10 kΩ or higher kΩ If the result is not as specified, replace the fuel lid lock with motor assembly.
- Measure the resistance according to the value(s) in the table below.
- Measure the shaft stroke.
Standard
Area Condition Specified Condition Shaft stroke Lever pulled 16.05 mm
(0.632 in.)If the result is not as specified, replace the fuel lid lock with motor assembly.
- Check the operation of the fuel lid lock with motor assembly (motor operation).