Operating Light Control Rheostat does not Change Light Brightness [06/2018 - 09/2022]: Procedure
- CHECK SYMPTOMS
- Ask the customer about the problem symptoms.
Result
Result Proceed to Meter illumination does not change when operating the light control rheostat A Tail cancel switch malfunction B
Result:
B
See step 5
Result:
A
See step 2
- Ask the customer about the problem symptoms.
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Rheostat value Light control rheostat input Min.: 0.00%, Max.: 100.01% or Unset Increases from 0 to 100 as light control rheostat turned from low to high "Unset" is displayed when the light control rheostat is moved to the highest position (tail cancel switch is turned on). Body Electrical > Combination Meter > Data List
Tester Display Rheostat value OK
The value displayed on the Techstream changes according to the actual light control rheostat operation.
Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [06/2018 - 01/2019] , or refer to REMOVAL [01/2019 - 03/2019] , or refer to REMOVAL [03/2019 - 09/2022]
Result:
NG
See step 3
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat.
Refer to REMOVAL [06/2018 - ]
- Inspect the light control rheostat.
Refer to INSPECTION [06/2018 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE LIGHT CONTROL RHEOSTAT. Refer to REMOVAL [06/2018 - ]
Result:
OK
See step 4
- Remove the light control rheostat.
- CHECK HARNESS AND CONNECTOR (LIGHT CONTROL RHEOSTAT - COMBINATION METER ASSEMBLY)
- Disconnect the I27 light control rheostat connector.
- Disconnect the I4 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition I27-5 (T) - I4-34 (SW1) Always Below 1 Ω I27-4 (RV) - I4-16 (SW2) Always Below 1 Ω I27-2 (E) - I4-11 (SW3) Always Below 1 Ω I27-5 (T) or I4-34 (SW1) - Body ground Always 10 kΩ or higher I27-4 (RV) or I4-16 (SW2) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [06/2018 - 01/2019] , or refer to REMOVAL [01/2019 - 03/2019] , or refer to REMOVAL [03/2019 - 09/2022]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Meter Day Mode Switch Tail cancel switch (Light control rheostat) OFF or ON OFF: Tail cancel switch off
ON: Tail cancel switch onWhen the light control rheostat is moved to the highest position, the tail cancel switch will turn on. Body Electrical > Combination Meter > Data List
Tester Display Meter Day Mode Switch OK
Normal conditions listed above are displayed.
Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [06/2018 - 01/2019] , or refer to REMOVAL [01/2019 - 03/2019] , or refer to REMOVAL [03/2019 - 09/2022]
Result:
NG
See step 6
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat.
Refer to REMOVAL [06/2018 - ]
- Inspect the light control rheostat.
Refer to INSPECTION [06/2018 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE LIGHT CONTROL RHEOSTAT. Refer to REMOVAL [06/2018 - ]
Result:
OK
See step 7
- Remove the light control rheostat.
- CHECK HARNESS AND CONNECTOR (LIGHT CONTROL RHEOSTAT - COMBINATION METER ASSEMBLY)
- Disconnect the I27 light control rheostat connector.
- Disconnect the I4 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition I27-5 (T) - I4-34 (SW1) Always Below 1 Ω I27-3 (TC) - I4-17 (TC) Always Below 1 Ω I27-5 (T) or I4-34 (SW1) - Body ground Always 10 kΩ or higher I27-3 (TC) or I4-17 (TC) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [06/2018 - 01/2019] , or refer to REMOVAL [01/2019 - 03/2019] , or refer to REMOVAL [03/2019 - 09/2022]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR