The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during transmission wire removal/installation are shown below.

NECESSARY PROCEDURE AFTER PARTS REMOVED/INSTALLED/REPLACED

Replaced Part or Performed Procedure Necessary Procedure Effect/Inoperative Function when Necessary Procedure not Performed Link
Battery terminal is disconnected/reconnected Drive the vehicle until stop and start control is permitted (approximately 5 to 60 minutes) Stop and start system Refer to PRECAUTION [10/2023 - ]
Perform steering sensor zero point calibration Lane control system Refer to INITIALIZATION [12/2021 - ]
Parking support brake system (for Gasoline model)*1
Pre-collision system
Reset back door close position Power back door system (for Gasoline model) Refer to INITIALIZATION [10/2023 - ]
Back door lock initialization*2 Power door lock control system Refer to INITIALIZATION [11/2018 - ]

*1: When performing learning using the Techstream.

*2: w/o Power Back Door System

NOTE:

After the ignition switch is turned off, the radio and display receiver assembly records various types of memory and settings. As a result, after turning the ignition switch off, be sure to wait for the time specified in the following table before disconnecting the cable from the negative (-) battery terminal.

WAITING TIME BEFORE DISCONNECTING CABLE FROM NEGATIVE (-) BATTERY TERMINAL

System Name See Procedure
Vehicle enrolled in Toyota Audio Multimedia system or safety connect system 6 minutes
Vehicle not enrolled in Toyota Audio Multimedia system and safety connect system 1 minute