Weak Blower Output [11/2018 - ]: Procedure
- CHECK BLOWER FAN OPERATION
- Prepare the vehicle according to the table below in manual mode.
Blower Switch Condition LO → HI - Temperature setting: Max COLD
- Mode switch: FACE
- A/C switch: Off
OK
Airflow volume is changed.
Result
Proceed to OK NG
Result:
NG
GO TO BLOWER MOTOR CIRCUIT. Refer to Blower Motor Circuit [11/2018 - 02/2019] , or refer to Blower Motor Circuit [02/2019 - ]
Result:
OK
See step 2
- Prepare the vehicle according to the table below in manual mode.
- CHECK ECO DRIVE MODE OPERATION
- Confirm setup of the ECO drive mode and turn it off if it is on.
HINT:
- When ECO drive mode is on, the air conditioning amplifier assembly ensures a minimum level of air conditioning control based on certain conditions, thereby contributing to improved fuel efficiency. Accordingly, explain to customers that the air volume will be weaker in these situations.
Control Control Summary Airflow Control Automatically switches the air inlet port to the internal air circulation mode when the outside air temperature is equal to or higher than a predetermined temperature and reduces the power consumption. Air Inlet Control Sets the blower level in AUTO mode lower than normal, and suppresses the power consumption. - If integration control and panel assembly (ECO switch) is malfunctioning, perform diagnosis on the ECO switch circuit.
Refer to ECO Switch Circuit [11/2018 - 02/2019] , or refer to ECO Switch Circuit [02/2019 - ]
Result
Proceed to NEXT - When ECO drive mode is on, the air conditioning amplifier assembly ensures a minimum level of air conditioning control based on certain conditions, thereby contributing to improved fuel efficiency. Accordingly, explain to customers that the air volume will be weaker in these situations.
Result:
NEXT
See step 3
- Confirm setup of the ECO drive mode and turn it off if it is on.
- CHECK CLEAN AIR FILTER
- Visually check the clean air filter.
OK
The clean air filter is not dirty or clogging.
Result
Proceed to OK NG
Result:
NG
REPLACE CLEAN AIR FILTER. Refer to DISASSEMBLY [11/2018 - ]
Result:
OK
See step 4
- Visually check the clean air filter.
- CHECK NO. 1 COOLER THERMISTOR
- Check the installation condition of the No. 1 cooler thermistor.
OK
No. 1 cooler thermistor is installed correctly.
Result
Proceed to OK NG
Result:
NG
REINSTALL NO. 1 COOLER THERMISTOR. Refer to INSTALLATION [11/2018 - 02/2019] , or refer to INSTALLATION [02/2019 - 08/2020] , or refer to INSTALLATION [08/2020 - ]
Result:
OK
See step 5
- Check the installation condition of the No. 1 cooler thermistor.
- CHECK ASPIRATOR
- Check the installation condition of the aspirator.
OK
Aspirator is installed correctly.
Result
Proceed to OK NG
Result:
OK
REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR (HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR WAS CLOGGING)
Result:
NG
REINSTALL ASPIRATOR. Refer to REASSEMBLY [11/2018 - 02/2019] , or refer to REASSEMBLY [02/2019 - 08/2020] , or refer to REASSEMBLY [08/2020 - ]
- Check the installation condition of the aspirator.