Blower Motor Circuit [11/2018 - 02/2019]: Procedure
- PERFORM ACTIVE TEST USING TECHSTREAM (BLOWER MOTOR)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Active Test.
- Perform the Active Test according to the display on the Techstream.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Blower Motor Blower with fan motor sub-assembly Min.: 0
Max.: 31- Body Electrical > Air Conditioner > Active Test
Tester Display Blower Motor OK
Blower with fan motor sub-assembly is operated.
Result
Proceed to OK NG
Result:
NG
See step 5
Result:
OK
See step 2
- CHECK HARNESS AND CONNECTOR (BLOWER WITH FAN MOTOR SUB-ASSEMBLY - BATTERY AND BODY GROUND)
- Disconnect the blower with fan motor sub-assembly connector.
*a Rear view of wire harness connector
(to Blower with Fan Motor Sub-assembly) - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A21-1 (GND) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition A21-3 (+B) - Body ground Power switch off 11 to 14 V Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 3
- Disconnect the blower with fan motor sub-assembly connector.
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BLOWER WITH FAN MOTOR SUB-ASSEMBLY)
- Disconnect the G46 air conditioning amplifier assembly connector.
- Disconnect the A21 blower with fan motor sub-assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G46-21 (BLW) - A21-2 (SI) Always Below 1 Ω G46-21 (BLW) or A21-2 (SI) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 4
- CHECK BLOWER WITH FAN MOTOR SUB-ASSEMBLY
- Disconnect the air conditioning amplifier assembly connector.
*a Front view of wire harness connector
(to Air Conditioning Amplifier Assembly) - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition G46-21 (BLW) - Body ground Always 4.75 to 5.25 V Result
Proceed to OK NG
Result:
NG
REPLACE BLOWER WITH FAN MOTOR SUB-ASSEMBLY. Refer to REMOVAL [11/2018 - ]
Result:
OK
See step 5
- Disconnect the air conditioning amplifier assembly connector.
- CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
- Using the oscilloscope, check for the waveform.
*a Component with harness connected
(Blower with Fan Motor Sub-assembly)Item Content Terminal No. A21-2 (SI) - Body ground Tool Setting 1 V/DIV., 500 μs./DIV. Vehicle Condition - Power switch on (IG)
- Blower switch: LO
HINT:
The waveform varies with the blower speed.
OK
Waveform is similar to that shown in the illustration.
Result
Proceed to OK NG
Result:
OK
REPLACE BLOWER WITH FAN MOTOR SUB-ASSEMBLY. Refer to DISASSEMBLY [11/2018 - ]
Result:
NG
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [11/2018 - ]
- Using the oscilloscope, check for the waveform.