Front Fog Light Circuit [11/2018 - 02/2019]: Procedure
- PERFORM ACTIVE TEST USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Main Body / Active Test.
- Perform the Active Test according to the display on the Techstream.
Body Electrical > Main Body > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Front Fog Light Relay Front fog light relay OFF or ON Light control switch in TAIL position Body Electrical > Main Body > Active Test
Tester Display Front Fog Light Relay OK
Front fog light relay operates. (Front fog lights come on.)
Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE
Refer to PROBLEM SYMPTOMS TABLE [11/2018 - 02/2019]
Result:
NG
See step 2
- CHECK HARNESS AND CONNECTOR (FOG FR RELAY - BATTERY)
- Remove the FOG FR relay.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 5 (FOG FR relay) - Body ground Always 11 to 14 V *a Front view of wire harness connector
(to FOG FR Relay)Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 3
- CHECK HARNESS AND CONNECTOR (FOG FR RELAY INPUT VOLTAGE)
- Remove the FOG FR relay.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition 2 (FOG FR relay) - Body ground Light control switch in TAIL or HEAD position 11 to 14 V *a Front view of wire harness connector
(to FOG FR Relay)Result
Proceed to OK NG
Result:
NG
See step 8
Result:
OK
See step 4
- INSPECT FOG FR RELAY
- Remove the FOG FR relay.
- Inspect the FOG FR relay.
Refer to ON-VEHICLE INSPECTION [11/2018 - 02/2019]
Result
Proceed to OK NG
Result:
NG
REPLACE FOG FR RELAY
Result:
OK
See step 5
- CHECK HARNESS AND CONNECTOR (FOG FR RELAY - FOG LIGHT ASSEMBLY)
- Remove the FOG FR relay.
- Disconnect the B11 fog light assembly LH connector.
- Disconnect the B10 fog light assembly RH connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 (FOG FR relay) - B10-2 (B) Always Below 1 Ω 3 (FOG FR relay) - B11-2 (B) Always Below 1 Ω 3 (FOG FR relay) or B10-2 (B) - Body ground Always 10 kΩ or higher 3 (FOG FR relay) or B11-2 (B) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 6
- CHECK HARNESS AND CONNECTOR (FOG FR RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Remove the FOG FR relay.
- Disconnect the 4A instrument panel junction block assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 (FOG FR relay) - 4A-52 Always Below 1 Ω 1 (FOG FR relay) or 4A-52 - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 7
- INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
*a Component without harness connected
(Instrument Panel Junction Block Assembly)- - - Remove the instrument panel junction block assembly.
Refer to REMOVAL [11/2018 - 02/2019]
- Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 4A-52 - A-7 (FFGO) Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)
Refer to REMOVAL [11/2018 - 02/2019]
Result:
NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
Refer to REMOVAL [11/2018 - 02/2019]
- Remove the instrument panel junction block assembly.
- CHECK HARNESS AND CONNECTOR (FOG FR RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Remove the FOG FR relay.
- Disconnect the 4F instrument panel junction block assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 2 (FOG FR relay) - 4F-32 Always Below 1 Ω 2 (FOG FR relay) or 4F-32 - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
Refer to REMOVAL [11/2018 - 02/2019]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR