Daytime Running Light Circuit [11/2018 - 02/2019]: Procedure
- CHECK OPERATION (LOW BEAM HEADLIGHTS)
- Check the operation of the low beam headlights.
OK
The low beam headlights operate normally.
Result
Proceed to OK NG
Result:
NG
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [11/2018 - 02/2019]
Result:
OK
See step 2
- Check the operation of the low beam headlights.
- PERFORM ACTIVE TEST USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Main Body / Active Test.
- Perform the Active Test according to the display on the Techstream.
Body Electrical > Main Body > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Daytime Running Light Daytime running lights OFF or ON - Body Electrical > Main Body > Active Test
Tester Display Daytime Running Light OK
Daytime running lights illuminate.
Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [11/2018 - 02/2019]
Result:
NG
See step 3
- CHECK HARNESS AND CONNECTOR (HEADLIGHT UNIT ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Disconnect the A62 headlight unit assembly LH connector.
- Disconnect the A61 headlight unit assembly RH connector.
- Disconnect the 4F instrument panel junction block assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A62-3 (B) - 4F-28 Always Below 1 Ω A61-3 (B) - 4F-28 Always Below 1 Ω A62-3 (B) or 4F-28 - Body ground Always 10 kΩ or higher A61-3 (B) or 4F-28 - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 4
- INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
*a Component without harness connected
(Instrument Panel Junction Block Assembly)- - - Remove the instrument panel junction block assembly.
Refer to REMOVAL [11/2018 - 02/2019]
- Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 4F-28 - A-25 (DRL) Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to REMOVAL [11/2018 - 02/2019]
Result:
NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL [11/2018 - 02/2019]
- Remove the instrument panel junction block assembly.