Back-up Light Circuit [11/2015 -]: Procedure

  1. CHECK FOR DTC (HYBRID CONTROL SYSTEM) 
    1. Clear the DTCs.

      for Nickel Metal Hydride Battery: Refer to DTC CHECK / CLEAR [11/2015 - 11/2017] , or refer to DTC CHECK / CLEAR [11/2017 - 12/2018] , or refer to DTC CHECK / CLEAR [12/2018 -]

      for Lithium-ion Battery: Refer to DTC CHECK / CLEAR [11/2015 - 11/2017] , or refer to DTC CHECK / CLEAR [11/2017 -]

      Powertrain > Hybrid Control > Clear DTCs 

    2. Check for DTCs.

      for Nickel Metal Hydride Battery: Refer to DTC CHECK / CLEAR [11/2015 - 11/2017] , or refer to DTC CHECK / CLEAR [11/2017 - 12/2018] , or refer to DTC CHECK / CLEAR [12/2018 -]

      for Lithium-ion Battery: Refer to DTC CHECK / CLEAR [11/2015 - 11/2017] , or refer to DTC CHECK / CLEAR [11/2017 -]

      Powertrain > Hybrid Control > Trouble Codes 

      Result

      Result Proceed to
      Hybrid control system DTCs are not output A
      Hybrid control system DTCs are output B

    Result: 

    GO TO HYBRID CONTROL SYSTEM 

    for Nickel Metal Hydride Battery: Refer to DIAGNOSTIC TROUBLE CODE CHART [11/2015 - 11/2017] , or refer to DIAGNOSTIC TROUBLE CODE CHART [11/2017 - 12/2018] , or refer to DIAGNOSTIC TROUBLE CODE CHART [12/2018 - 08/2019] , or refer to DIAGNOSTIC TROUBLE CODE CHART [08/2019 - 06/2021] , or refer to DIAGNOSTIC TROUBLE CODE CHART [06/2021 -]

    for Lithium-ion Battery: Refer to DIAGNOSTIC TROUBLE CODE CHART [11/2015 - 11/2017] , or refer to DIAGNOSTIC TROUBLE CODE CHART [11/2017 - 12/2018] , or refer to DIAGNOSTIC TROUBLE CODE CHART [12/2018 - 08/2019] , or refer to DIAGNOSTIC TROUBLE CODE CHART [08/2019 - 06/2021] , or refer to DIAGNOSTIC TROUBLE CODE CHART [06/2021 -]

    Result: 

    See step  2

  2. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - BODY GROUND) 
    1. Disconnect the 3D instrument panel junction block assembly connector.
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      3D-3 - Body ground Always Below 1 Ω

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR 

    Result: 

    OK 

    See step  3

  3. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - HYBRID VEHICLE CONTROL ECU) 
    1. Disconnect the 3F instrument panel junction block assembly connector.
    2. Disconnect the A50 hybrid vehicle control ECU connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      (A50)

      (A50)

      Tester Connection Condition Specified Condition
      3F-19 - A50-20 (BL) Always Below 1 Ω
      3F-19 or A50-20 (BL) - Body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR 

    Result: 

    OK 

    See step  4

  4. CHECK HYBRID VEHICLE CONTROL ECU (OUTPUT VOLTAGE) 
    1. Reconnect the A50 hybrid vehicle control ECU connector.
    2. Reconnect the 3F instrument panel junction block assembly connector.
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection Condition Specified Condition
      3F-19 - Body ground Power switch on (IG), reverse (R) not selected Below 1 V
      3F-19 - Body ground Power switch on (IG), reverse (R) selected 11 to 14 V

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPLACE HYBRID VEHICLE CONTROL ECU. Refer to  REMOVAL [11/2015 - 12/2018]  , or refer to  REMOVAL [12/2018 - 08/2019]  , or refer to  REMOVAL [08/2019 - 07/2020]  , or refer to  REMOVAL [07/2020 -] 

    Result: 

    OK 

    See step  5

  5. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (OUTPUT VOLTAGE) 
    1. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection Condition Specified Condition
      3H-10 - Body ground Power switch on (IG), reverse (R) not selected Below 1 V
      3H-10 - Body ground Power switch on (IG), reverse (R) selected 11 to 14 V

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPAIR OR REPLACE HARNESS OR CONNECTOR (REAR COMBINATION LIGHT ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY) 

    Result: 

    NG 

    REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to  REMOVAL [11/2015 - 12/2018]  , or refer to  REMOVAL [12/2018 - 07/2020]  , or refer to  REMOVAL [07/2020 -]