Operating Light Control Rheostat does not Change Light Brightness [11/2021 - ]: Procedure
- READ VALUE USING GTS
- Read the Data List according to the display on the GTS.
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Diagnostic Note Illumination control switch input state Input condition of light control rheostat is displayed 0 to 100 % - Body Electrical > Combination Meter > Data List
Tester Display Illumination control switch input state OK
Depending on the operation of the light control rheostat, the value of 0 to 100 is displayed in the Data List item.
Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [11/2021 - ]
Result:
NG
See step 2
- Read the Data List according to the display on the GTS.
- READ VALUE USING GTS
- Read the Data List according to the display on the GTS.
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Diagnostic Note Bright switch input state Input condition of bright switch is displayed - OFF
- ON
- Body Electrical > Combination Meter > Data List
Tester Display Bright switch input state OK
The value of the Data List item is correct.
Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [11/2021 - ]
Result:
NG
See step 3
- Read the Data List according to the display on the GTS.
- INSPECT LIGHT CONTROL RHEOSTAT
Refer to INSPECTION [11/2021 - ]
Result
Proceed to OK NG Result:
NG
REPLACE LIGHT CONTROL RHEOSTAT. Refer to REMOVAL [11/2021 - ]
Result:
OK
See step 4
- CHECK HARNESS AND CONNECTOR (LIGHT CONTROL RHEOSTAT - COMBINATION METER ASSEMBLY AND BODY GROUND)
- Disconnect the F22 light control rheostat connector.
- Disconnect the F11 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition F22-4 - F11-31(ILLUMI CONTROL SW POWER) Always Below 1 Ω F22-1 - F11-32(BRIGHT (ILLUMI CANCEL) SW) Always Below 1 Ω F22-5 - F11-30(ILLUMI CONTROL SW VR) Always Below 1 Ω F22-6 - F11-29(ILLUMI CONTROL SW GND) Always Below 1 Ω F22-4 or F11-31(ILLUMI CONTROL SW POWER) - Body ground Always 10 kΩ or higher F22-1 or F11-32(BRIGHT (ILLUMI CANCEL) SW) - Body ground Always 10 kΩ or higher F22-5 or F11-30(ILLUMI CONTROL SW VR) - Body ground Always 10 kΩ or higher F22-6 or F11-29(ILLUMI CONTROL SW GND) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [11/2021 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR