DTC B1507: Outside Temperature Sensor Open Detected [11/2021 - ]: Procedure
- CHECK FOR DTC
- Check for DTCs.
Body Electrical > Combination Meter > Trouble Codes
OK
DTC B1507 (current code) is not output.
Result
Proceed to OK NG
Result:
NG
See step 3
Result:
OK
See step 2
- Check for DTCs.
- CHECK CONNECTOR
- Disconnect the A24 ambient temperature sensor(thermistor assembly) connector.
- Disconnect the F11 combination meter assembly connector.
- Check the condition of each connector.
OK
Each connector is normal.
Result
Proceed to OK NG
Result:
OK
USE SIMULATION METHOD TO CHECK
HINT:
- Even if DTC is displayed, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
- In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
Result:
NG
REPAIR OR REPLACE THE POOR CONTACT OF CONNECTOR.
- READ VALUE USING GTS
- Read the Data List according to the display on the GTS.
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Diagnostic Note Ambient air temperature External temperature sensor value display -40 - 80 °C (-40 to 176 °F) - Body Electrical > Combination Meter > Data List
Tester Display Ambient air temperature OK
The value of the Data List item is correct.
Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [11/2021 - ]
Result:
NG
See step 4
- Read the Data List according to the display on the GTS.
- INSPECT AMBIENT TEMPERATURE SENSOR(THERMISTOR ASSEMBLY)
Refer to INSPECTION [11/2021 - ]
Result
Proceed to OK NG Result:
NG
REPLACE AMBIENT TEMPERATURE SENSOR(THERMISTOR ASSEMBLY). Refer to REMOVAL [11/2021 - ]
Result:
OK
See step 5
- CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR(THERMISTOR ASSEMBLY) - COMBINATION METER ASSEMBLY AND BODY GROUND)
- Disconnect the A24 ambient temperature sensor(thermistor assembly) connector.
- Disconnect the F11 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A24-2 - F11-23(OUT TEMP SENSOR+) Always Below 10 Ω A24-1 - F11-24(OUT TEMP SENSOR GND) Always Below 10 Ω A24-2 or F11-23(OUT TEMP SENSOR+) - Body ground Always 10 kΩ or higher A24-1 or F11-24(OUT TEMP SENSOR GND) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [11/2021 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR