Caution / Notice / Hint
WARNING: This page is about a different car, the 2025 Toyota Corolla Cross, 2024 Toyota Corolla Cross, and 2023 Toyota Corolla Cross. However, it is still accessible from the selected car via links, so may be relevant.
WARNING:
Refer to the precautions before inspecting high voltage circuit.
Refer to PRECAUTION [11/2022 - 12/2024] , or refer to PRECAUTION [12/2024 - ]
NOTE:
- If the DTCs are cleared or the cable is disconnected and reconnected to the negative (-) auxiliary battery terminal before performing repairs, turning the ignition switch to ON (READY) may cause a malfunction. Do not turn the ignition switch to ON (READY).
- After the ignition switch is turned off, there may be a waiting time before disconnecting the negative (-) auxiliary battery terminal.
Refer to BEFORE DISCONNECTING BATTERY [11/2022 - 11/2023] , or refer to BEFORE DISCONNECTING BATTERY [11/2023 - ]
- When disconnecting and reconnecting the auxiliary battery
HINT:
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
HINT:
- If DTC P0AA0-00 is output, the ignition switch cannot be turned to ON (READY).
- P0AA0-00 may be output as a result of the malfunction indicated by the DTCs in table below.
- The chart above is listed in inspection order of priority.
- Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Hybrid Control System | P0606-47 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure |
| P0606-87 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message | ||
| P060A-47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure | ||
| P060A-87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message | ||
| P0A1B-49 | Drive Motor "A" Control Module Internal Electronic Failure | ||
| P1C9E-9F | Hybrid/EV System Reset Stuck Off | ||
| Motor Generator Control System | P0A1B-1F | Generator Control Module Circuit Intermittent | |
| P0A1A-47 | Generator Control Module Watchdog / Safety MC Failure | ||
| P0A1A-49 | Generator Control Module Internal Electronic Failure | ||
| P1C2A-1C | Generator A/D Converter Circuit Voltage Out of Range | ||
| P1C2A-49 | Generator A/D Converter Circuit Internal Electronic Failure | ||
| P1C2B-1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range | ||
| P1C2B-49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure | ||
| P1CAC-49 | Generator Position Sensor Internal Electronic Failure | ||
| P1CAD-49 | Drive Motor "A" Position Sensor Internal Electronic Failure | ||
| P1CAF-38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect | ||
| P1CB0-38 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect | ||
| P3133-83 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect | ||
| P3133-86 | Communication Error from Generator to Drive Motor "A" Signal Invalid | ||
| Power source circuit malfunction | Motor Generator Control System | P06D6-1C | Generator Control Module Offset Power Circuit Voltage Out of Range |
| P06B0-1C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range | ||
| Communication system malfunction | Motor Generator Control System | P3133-87 | Communication Error from Generator to Drive Motor "A" Missing Message |
| Sensor and actuator circuit malfunction | Hybrid Control System | P0AD9-11 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
| P0AD9-15 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open | ||
| P0ADD-11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground | ||
| P0ADD-15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open | ||
| Motor Generator Control System | P0A3F-16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold | |
| P0A4B-16 | Generator Position Sensor Circuit Voltage Below Threshold | ||
| P0A4B-21 | Generator Position Sensor Signal Amplitude < Minimum | ||
| P0A4B-22 | Generator Position Sensor Signal Amplitude > Maximum | ||
| P0C50-13 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open | ||
| P0C50-16 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
| P0C50-17 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
| P0C5A-13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open | ||
| P0C5A-16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
| P0C5A-17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
| P0C64-13 | Generator Position Sensor Circuit "A" Circuit Open | ||
| P0C64-16 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
| P0C64-17 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
| P0C69-13 | Generator Position Sensor Circuit "B" Circuit Open | ||
| P0C69-16 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
| P0C69-17 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
| System malfunction | Hybrid Control System | P0D2D-1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range |
| P1C83-49 | High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction | ||
| P0C76-00 | Hybrid/EV Battery System Discharge Time Too Long | ||
| Motor Generator Control System | P0D2D-16 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold | |
| P0D2D-17 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold | ||
| P1CB6-9E | Drive Motor "A" Inverter Voltage Sensor (VH) Stuck On | ||