LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2022 >> Corolla Cross L, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 25 (Heating / Air Conditioning System (Except HEV, Auto A/C) - Diagnostic Codes & Symptom Tests) >> AIR CONDITIONING SYSTEM (for Gasoline Model with Automatic Air Conditioning System) >> No Cool Air Comes Out [11/2022 - ] >> Procedure

No Cool Air Comes Out [11/2022 - ]: Procedure

WARNING: This page is about a different car, the 2025 Toyota Corolla Cross, 2024 Toyota Corolla Cross, and 2023 Toyota Corolla Cross. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK SWITCH INDICATOR 
    1. Operate each switch on the air conditioning control assembly and check that the switch indicators operate normally.

      OK

      All switch indicators operate normally.

      Result

        Proceed to
      OK (for Dual Type) A
      OK (for Single Type) B
      NG C

    Result: 

    See step  3

    Result: 

    GO TO OTHER DIAGNOSIS PROCEDURE (Operation not Accepted Even If Air Conditioning Switch is Operated). Refer to  Operation not Accepted Even If Air Conditioning Switch is Operated [11/2022 - ]  

    Result: 

    See step  2

  2. PERFORM ACTIVE TEST USING GTS 
    1. Perform the Active Test according to the display on the GTS.

      Body Electrical > Air Conditioner > Active Test 

      Tester Display Measurement Item Control Range Diagnostic Note
      Front Left Air Mix Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly pulse Min.: 128
      Max.: 384
      Operates between 165 to 257 pulses
      Front Right Air Mix Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly pulse Min.: 128
      Max.: 384
      Operates between 255 to 347 pulses

      Body Electrical > Air Conditioner > Active Test 

      Active Test Display
      Front Left Air Mix Damper Control Servo Motor
      Data List Display
      Front Left Air Mix Damper Control Servo Motor Actual Pulse

      Body Electrical > Air Conditioner > Active Test 

      Active Test Display
      Front Right Air Mix Damper Control Servo Motor
      Data List Display
      Front Right Air Mix Damper Control Servo Motor Actual Pulse

      OK

      The No. 1 air conditioning radiator damper servo motor operates.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET. Refer to  ON-VEHICLE INSPECTION [09/2021 - ] 

    Result: 

    NG 

    GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR. Refer to  DIAGNOSTIC TROUBLE CODE CHART [11/2022 - ] 

  3. PERFORM ACTIVE TEST USING GTS 
    1. Perform the Active Test according to the display on the GTS.

      Body Electrical > Air Conditioner > Active Test 

      Tester Display Measurement Item Control Range Diagnostic Note
      Front Air Mix Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly pulse Min.: 128
      Max.: 384
      Operates between 255 to 347 pulses

      Body Electrical > Air Conditioner > Active Test 

      Active Test Display
      Front Air Mix Damper Control Servo Motor
      Data List Display
      Front Air Mix Damper Control Servo Motor Actual Pulse

      OK

      The No. 1 air conditioning radiator damper servo motor operates.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET. Refer to  ON-VEHICLE INSPECTION [09/2021 - ] 

    Result: 

    NG 

    GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR. Refer to  DIAGNOSTIC TROUBLE CODE CHART [11/2022 - ]