Home >> Toyota >> 2022 >> Avalon XLE >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 65 (Air Conditioning System - Diagnostic Codes & Symptom Tests (Hybrid)) >> AIR CONDITIONING SYSTEM (for HV Model) >> Symptom Tests >> Air Vent Temperature does not Change and Right Vent is Different from Left and Vice Versa (Same Left/Right Temperature Setting) [04/2018 -] >> Procedure

Air Vent Temperature does not Change and Right Vent is Different from Left and Vice Versa (Same Left/Right Temperature Setting) [04/2018 -]: Procedure

WARNING: This page is about a different variant/trim than selected.
  1. CHECK WHEN MALFUNCTION OCCURS 

    Result

    Result  Proceed to
    When using cooling function A
    When using heater function B

    Result: 

    See step  6

    Result: 

    See step  2

  2. PERFORM REFRIGERANT SHORTAGE CHECK 
    1. Connect the Techstream to the DLC3.
    2. Turn the power switch on (IG).
    3. Turn the Techstream on.
    4. Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.

      Body Electrical > Air Conditioner > Utility 

      Tester Display
      Refrigerant Gas Volume Check
    5. Check that the following conditions are met and perform the refrigerant shortage check according to the display on the Techstream.
      MEASUREMENT CONDITION:

      Item Condition
      A/C switch On
      Ambient temperature* 0 to 49°C (32 to 120°F)
      Blower speed HI

      *: If the ambient temperature is not within the range shown, do not perform this check.

      Result

      Result Amount of Refrigerant
      Refrigerant correct Correct
      Refrigerant shortage Insufficient

      OK

      "Refrigerant correct" is displayed on the Techstream.

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    CHARGE SYSTEM WITH REFRIGERANT. Refer to  REPLACEMENT [04/2018 -] 

    Result: 

    OK 

    See step  3

  3. PERFORM ACTIVE TEST USING TECHSTREAM 
    1. Connect the Techstream to the DLC3.
    2. Turn the power switch on (IG).
    3. Turn the Techstream on.
    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.
    5. Perform the Active Test according to the display on the Techstream.

      Body Electrical > Air Conditioner > Active Test 

      Tester Display Measurement Item Control Range Diagnostic Note
      Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
      Max.: 383
      Operates between 165 and 257 pulses
      Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse Min.: 128
      Max.: 383
      Operates between 255 and 347 pulses

      Body Electrical > Air Conditioner > Active Test 

      Tester Display
      Air Mix Servo Targ Pulse(D)

      Body Electrical > Air Conditioner > Active Test 

      Tester Display
      Air Mix Servo Targ Pulse(P)

      OK

      Each damper servo motor operates.

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR. Refer to  DIAGNOSTIC TROUBLE CODE CHART [04/2018 - 08/2020]  , or refer to  DIAGNOSTIC TROUBLE CODE CHART [08/2020 -] 

    Result: 

    OK 

    See step  4

  4. CHECK HARNESS AND CONNECTOR (AUTOMATIC LIGHT CONTROL SENSOR - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)) 
    1. Disconnect the G23 automatic light control sensor connector.
    2. Disconnect the G33 main body ECU (multiplex network body ECU) connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      G23-1 (CLTB) - G33-23 (CLTB) Always Below 1 Ω
      G23-2 (CLTE) - G33-25 (CLTE) Always Below 1 Ω
      G23-4 (CLTS) - G33-24 (CLTS) Always Below 1 Ω
      G23-1 (CLTB) or G33-23 (CLTB) - Other terminals and body ground Always 10 kΩ or higher
      G23-2 (CLTE) or G33-25 (CLTE) - Other terminals and body ground Always 10 kΩ or higher
      G23-4 (CLTS) or G33-24 (CLTS) - Other terminals and body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR 

    Result: 

    OK 

    See step  5

  5. INSPECT AUTOMATIC LIGHT CONTROL SENSOR 
    1. Remove the automatic light control sensor.

      Refer to REMOVAL [04/2018 -]

    2. Inspect the automatic light control sensor.

      Refer to ON-VEHICLE INSPECTION [04/2018 -]

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET. Refer to  ON-VEHICLE INSPECTION [04/2018 -] 

    Result: 

    NG 

    REPLACE AUTOMATIC LIGHT CONTROL SENSOR. Refer to  REMOVAL [04/2018 -] 

  6. BLEED AIR FROM COOLING SYSTEM 
    1. Bleed air from cooling system.

      Refer to REPLACEMENT [04/2018 -]

      Result

      Proceed to
      NEXT

    Result: 

    NEXT 

    See step  7

  7. CHECK OPERATION (AIR CONDITIONING SYSTEM) 
    1. Set the same temperature for the left and right sides and check that the air that blows from the left and right front registers is the same temperature.

      OK

      The air from the left and right front registers is the same temperature.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    END (MALFUNCTION DUE TO AIR IN COOLING SYSTEM) 

    Result: 

    NG 

    See step  8

  8. PERFORM ACTIVE TEST USING TECHSTREAM 
    1. Connect the Techstream to the DLC3.
    2. Turn the power switch on (IG).
    3. Turn the Techstream on.
    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.
    5. Perform the Active Test according to the display on the Techstream.

      Body Electrical > Air Conditioner > Active Test 

      Tester Display Measurement Item Control Range Diagnostic Note
      Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
      Max.: 383
      Operates between 165 and 257 pulses
      Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse Min.: 128
      Max.: 383
      Operates between 255 and 347 pulses

      Body Electrical > Air Conditioner > Active Test 

      Tester Display
      Air Mix Servo Targ Pulse(D)

      Body Electrical > Air Conditioner > Active Test 

      Tester Display
      Air Mix Servo Targ Pulse(P)

      OK

      Each damper servo motor operates.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY. Refer to  DISASSEMBLY [04/2018 - 08/2019]  , or refer to  DISASSEMBLY [08/2019 -] 

    Result: 

    NG 

    GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR. Refer to  DIAGNOSTIC TROUBLE CODE CHART [04/2018 - 08/2020]  , or refer to  DIAGNOSTIC TROUBLE CODE CHART [08/2020 -]