Air Vent Temperature does not Change and Right Vent is Different from Left and Vice Versa (Same Left/Right Temperature Setting) [04/2018 -]: Procedure
- CHECK WHEN MALFUNCTION OCCURS
Result
Result Proceed to When using cooling function A When using heater function B Result:
B
See step 6
Result:
A
See step 2
- PERFORM REFRIGERANT SHORTAGE CHECK
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
Body Electrical > Air Conditioner > Utility
Tester Display Refrigerant Gas Volume Check - Check that the following conditions are met and perform the refrigerant shortage check according to the display on the Techstream.MEASUREMENT CONDITION:
Item Condition A/C switch On Ambient temperature* 0 to 49°C (32 to 120°F) Blower speed HI *: If the ambient temperature is not within the range shown, do not perform this check.
Result
Result Amount of Refrigerant Refrigerant correct Correct Refrigerant shortage Insufficient OK
"Refrigerant correct" is displayed on the Techstream.
Result
Proceed to OK NG
Result:
NG
CHARGE SYSTEM WITH REFRIGERANT. Refer to REPLACEMENT [04/2018 -]
Result:
OK
See step 3
- PERFORM ACTIVE TEST USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Active Test.
- Perform the Active Test according to the display on the Techstream.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383Operates between 165 and 257 pulses Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse Min.: 128
Max.: 383Operates between 255 and 347 pulses Body Electrical > Air Conditioner > Active Test
Tester Display Air Mix Servo Targ Pulse(D) Body Electrical > Air Conditioner > Active Test
Tester Display Air Mix Servo Targ Pulse(P) OK
Each damper servo motor operates.
Result
Proceed to OK NG
Result:
NG
GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR. Refer to DIAGNOSTIC TROUBLE CODE CHART [04/2018 - 08/2020] , or refer to DIAGNOSTIC TROUBLE CODE CHART [08/2020 -]
Result:
OK
See step 4
- CHECK HARNESS AND CONNECTOR (AUTOMATIC LIGHT CONTROL SENSOR - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))
- Disconnect the G23 automatic light control sensor connector.
- Disconnect the G33 main body ECU (multiplex network body ECU) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G23-1 (CLTB) - G33-23 (CLTB) Always Below 1 Ω G23-2 (CLTE) - G33-25 (CLTE) Always Below 1 Ω G23-4 (CLTS) - G33-24 (CLTS) Always Below 1 Ω G23-1 (CLTB) or G33-23 (CLTB) - Other terminals and body ground Always 10 kΩ or higher G23-2 (CLTE) or G33-25 (CLTE) - Other terminals and body ground Always 10 kΩ or higher G23-4 (CLTS) or G33-24 (CLTS) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 5
- INSPECT AUTOMATIC LIGHT CONTROL SENSOR
- Remove the automatic light control sensor.
Refer to REMOVAL [04/2018 -]
- Inspect the automatic light control sensor.
Refer to ON-VEHICLE INSPECTION [04/2018 -]
Result
Proceed to OK NG
Result:
OK
INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET. Refer to ON-VEHICLE INSPECTION [04/2018 -]
Result:
NG
REPLACE AUTOMATIC LIGHT CONTROL SENSOR. Refer to REMOVAL [04/2018 -]
- Remove the automatic light control sensor.
- BLEED AIR FROM COOLING SYSTEM
- Bleed air from cooling system.
Refer to REPLACEMENT [04/2018 -]
Result
Proceed to NEXT
Result:
NEXT
See step 7
- Bleed air from cooling system.
- CHECK OPERATION (AIR CONDITIONING SYSTEM)
- Set the same temperature for the left and right sides and check that the air that blows from the left and right front registers is the same temperature.
OK
The air from the left and right front registers is the same temperature.
Result
Proceed to OK NG
Result:
OK
END (MALFUNCTION DUE TO AIR IN COOLING SYSTEM)
Result:
NG
See step 8
- Set the same temperature for the left and right sides and check that the air that blows from the left and right front registers is the same temperature.
- PERFORM ACTIVE TEST USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Active Test.
- Perform the Active Test according to the display on the Techstream.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383Operates between 165 and 257 pulses Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse Min.: 128
Max.: 383Operates between 255 and 347 pulses Body Electrical > Air Conditioner > Active Test
Tester Display Air Mix Servo Targ Pulse(D) Body Electrical > Air Conditioner > Active Test
Tester Display Air Mix Servo Targ Pulse(P) OK
Each damper servo motor operates.
Result
Proceed to OK NG
Result:
OK
REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY. Refer to DISASSEMBLY [04/2018 - 08/2019] , or refer to DISASSEMBLY [08/2019 -]
Result:
NG
GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR. Refer to DIAGNOSTIC TROUBLE CODE CHART [04/2018 - 08/2020] , or refer to DIAGNOSTIC TROUBLE CODE CHART [08/2020 -]