DTC B1423: Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure [04/2018 -]: Procedure
- CHECK FOR DTC
- Check for DTCs.
Body Electrical > Air Conditioner > Trouble Codes
Result
Result Proceed to B14B8 is not output A B14B8 is output B
Result:
B
GO TO DTC B14B8. Refer to DTC B14B8: Refrigerant Shortage [04/2018 -]
Result:
A
See step 2
- Check for DTCs.
- COMPARE REFRIGERANT GAS PRESSURE VALUES SHOWN ON TECHSTREAM AND MANIFOLD GAUGE SET
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Regulator Pressure Sensor Air conditioner pressure sensor Min.: -456.68 kPaG
Max.: 3294.37 kPaGActual refrigerant pressure displayed - Refrigerant line (gas leak etc.)
- Air conditioner pressure sensor circuit malfunction
Body Electrical > Air Conditioner > Data List
Tester Display Regulator Pressure Sensor - Install a manifold gauge set.
Refer to ON-VEHICLE INSPECTION [04/2018 -]
- Compare the values displayed in the Data List and on the manifold gauge set.
Result
Result Proceed to Data List value and manifold gauge set value do not match and Data List value: 176 kPaG (1.8 kgf/cm2 , 26 psi) or less A Data List value and manifold gauge set value do not match and Data List value: 3025 kPaG (30.8 kgf/cm2 , 439 psi) or more B Data List value matches manifold gauge set value C
Result:
B
See step 8
Result:
C
GO TO ON-VEHICLE INSPECTION (CHECK REFRIGERANT PRESSURE USING GAUGE). Refer to ON-VEHICLE INSPECTION [04/2018 -]
Result:
A
See step 3
- READ VALUE USING TECHSTREAM (REGULATOR PRESSURE SENSOR)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Regulator Pressure Sensor Air conditioner pressure sensor Min.: -456.68 kPaG
Max.: 3294.37 kPaGActual refrigerant pressure displayed - Refrigerant line (gas leak etc.)
- Air conditioner pressure sensor circuit malfunction
Body Electrical > Air Conditioner > Data List
Tester Display Regulator Pressure Sensor OK
Disconnecting the A15 connector of the air conditioner pressure sensor causes the Data List value to change.
Result
Result Proceed to Regulator pressure sensor value changes A Regulator pressure sensor value does not change B
Result:
B
See step 6
Result:
A
See step 4
- CHECK TERMINAL VOLTAGE (AIR CONDITIONER PRESSURE SENSOR)
- Measure the voltage according to the value(s) in the table below.
*a Front view of wire harness connector
(to Air Conditioner Pressure Sensor)Standard Voltage
Tester Connection Condition Specified Condition A15-3 (+) - Body ground Power switch on (IG) 4.75 to 5.25 V Result
Proceed to OK NG
Result:
OK
REPLACE AIR CONDITIONER PRESSURE SENSOR. Refer to REMOVAL [04/2018 -]
Result:
NG
See step 5
- Measure the voltage according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Disconnect the G36 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A15-3 (+) - G36-6 (S5-3) Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [04/2018 - 08/2020] , or refer to REMOVAL [08/2020 -]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK TERMINAL VOLTAGE (AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Measure the voltage according to the value(s) in the table below.
*a Front view of wire harness connector
(to Air Conditioner Pressure Sensor)Standard Voltage
Tester Connection Condition Specified Condition A15-2 (PR) - Body ground Power switch on (IG) 3.0 to 5.25 V Result
Proceed to OK NG
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [04/2018 - 08/2020] , or refer to REMOVAL [08/2020 -]
Result:
NG
See step 7
- Measure the voltage according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Disconnect the G36 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A15-2 (PR) or G36-24 (PRE) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [04/2018 - 08/2020] , or refer to REMOVAL [08/2020 -]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR
- Disconnect the A15 air conditioner pressure sensor connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A15-1 (-) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
NG
See step 14
Result:
OK
See step 9
- CHECK TERMINAL VOLTAGE
- Measure the voltage according to the value(s) in the table below.
*a Front view of wire harness connector
(to Air Conditioner Pressure Sensor)Standard Voltage
Tester Connection Condition Specified Condition A15-2 (PR) - Body ground Power switch on (IG) 3.0 to 5.25 V Result
Result Proceed to 5.25 V or higher A 3.0 to 5.25 V B Below 3.0 V C
Result:
B
See step 11
Result:
C
See step 13
Result:
A
See step 10
- Measure the voltage according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Disconnect the G36 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A15-2 (PR) or G36-24 (PRE) - Other terminals Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [04/2018 - 08/2020] , or refer to REMOVAL [08/2020 -]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK INTERNAL CIRCUIT RESISTANCE (AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A15-3 (+) - A15-2 (PR) Power switch off 180 to 220 kΩ HINT:
After turning the power switch off, wait at least 30 seconds before performing the measurement.
Result
Proceed to OK NG
Result:
OK
REPLACE AIR CONDITIONER PRESSURE SENSOR. Refer to REMOVAL [04/2018 -]
Result:
NG
See step 12
- Measure the resistance according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Disconnect the G36 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A15-2 (PR) or G36-24 (PRE) - A15-3 (+) or G36-6 (S5-3) Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [04/2018 - 08/2020] , or refer to REMOVAL [08/2020 -]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Disconnect the G36 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A15-2 (PR) - G36-24 (PRE) Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [04/2018 - 08/2020] , or refer to REMOVAL [08/2020 -]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Disconnect the G36 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A15-1 (-) - G36-3 (SG-4) Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [04/2018 - 08/2020] , or refer to REMOVAL [08/2020 -]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR