DTC B1411: Room Temperature Sensor Circuit [04/2018 -]: Procedure
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Room Temperature Sensor Cooler (room temp. sensor) thermistor Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)Actual cabin temperature displayed Cooler (room temp. sensor) thermistor circuit malfunction - When open circuit: -6.50°C (20.30°F)
- When short circuit: 57.25°C (135.05°F)
Body Electrical > Air Conditioner > Data List
Tester Display Room Temperature Sensor OK
The display is as specified in the normal condition column.
Result
Proceed to OK NG
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [04/2018 - 08/2020] , or refer to REMOVAL [08/2020 -]
Result:
NG
See step 2
- INSPECT COOLER (ROOM TEMP. SENSOR) THERMISTOR
- Remove the cooler (room temp. sensor) thermistor.
Refer to REMOVAL [04/2018 - 08/2021] , or refer to REMOVAL [08/2021 -]
- Inspect the cooler (room temp. sensor) thermistor.
Refer to INSPECTION [04/2018 -]
Result
Proceed to OK NG
Result:
NG
REPLACE COOLER (ROOM TEMP. SENSOR) THERMISTOR. Refer to REMOVAL [04/2018 - 08/2021] , or refer to REMOVAL [08/2021 -]
Result:
OK
See step 3
- Remove the cooler (room temp. sensor) thermistor.
- CHECK HARNESS AND CONNECTOR (COOLER (ROOM TEMP. SENSOR) THERMISTOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Disconnect the G36 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G44-1 - G36-14 (TR) Always Below 1 Ω G44-2 - G36-1 (SG-1) Always Below 1 Ω G44-1 or G36-14 (TR) - Other terminals and body ground Always 10 kΩ or higher G44-2 or G36-1 (SG-1) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [04/2018 - 08/2020] , or refer to REMOVAL [08/2020 -]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR