Odo/Trip Switch Malfunction [04/2018 - ]: Procedure
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note ODO/TRIP Change Switch ODO/TRIP switch (Trip switch) OFF or ON OFF: Switch released
ON: Switch pushed- Body Electrical > Combination Meter > Data List
Tester Display ODO/TRIP Change Switch OK
ODO/TRIP switch (trip switch) condition displayed on the Techstream changes with the actual switch operation.
Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [04/2018 - 08/2020] , or refer to REMOVAL [08/2020 - 08/2021] , or refer to REMOVAL [08/2021 - ]
Result:
NG
See step 2
- INSPECT TRIP SWITCH
- Remove the trip switch.
Refer to REMOVAL [04/2018 - ]
- Inspect the trip switch.
Refer to INSPECTION [04/2018 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE TRIP SWITCH. Refer to REMOVAL [04/2018 - ]
Result:
OK
See step 3
- Remove the trip switch.
- CHECK HARNESS AND CONNECTOR (TRIP SWITCH - COMBINATION METER ASSEMBLY)
- Disconnect the G15 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G80-3 (A/B) - G15-1 (ODO) Always Below 1 Ω G80-1 (E) - G15-5 (SW3) Always Below 1 Ω G80-3 (A/B) or G15-1 (ODO) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [04/2018 - 08/2020] , or refer to REMOVAL [08/2020 - 08/2021] , or refer to REMOVAL [08/2021 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR