Fuel Lid Opener System Operation Message Display Malfunction [04/2018 - ]: Procedure
- INSPECT COMBINATION METER ASSEMBLY (OUTPUT VOLTAGE)
*a Front view of wire harness connector
(to ECM)- Disconnect the A19 ECM connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition A19-41 (LSTM) - Body ground Always 11 to 14 V Result
Proceed to OK NG
Result:
NG
See step 3
Result:
OK
See step 2
- INSPECT COMBINATION METER ASSEMBLY (INPUT WAVEFORM)
*a Component with harness connected
(Combination Meter Assembly)- Connect the A19 ECM connector.
- Remove the combination meter assembly with the connector(s) still connected.
- Operate the fuel lid opener switch.
- Check the signal waveform according to the condition(s) in the table below.
- Waveform 1:
Item Condition Tester Connection G16-34 (LST1) - Body ground Tool setting 5 V/DIV., 20 ms./DIV. Condition "Ready to Refuel" displayed on multi-information display - Waveform 2:
Item Condition Tester Connection G16-34 (LST1) - Body ground Tool setting 5 V/DIV., 20 ms./DIV. Condition "Close Fuel Lid" displayed on multi-information display HINT:
This waveform is output when the fuel lid opener switch is operated if the fuel lid is open and any of the following conditions are met:
- The vehicle has been driven for 1 km (0.6 mile) or more at a speed of 50 km/h (31 mph) or more.
- 30 minutes or more have elapsed since the fuel lid opener switch was operated.
OK
All of the waveforms are output normally.
Result
Proceed to OK NG - Waveform 1:
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [04/2018 - 08/2020] , or refer to REMOVAL [08/2020 - 08/2021] , or refer to REMOVAL [08/2021 - ]
Result:
NG
REPLACE ECM. Refer to REMOVAL [04/2018 - 08/2020] , or refer to REMOVAL [08/2020 - 08/2021] , or refer to REMOVAL [08/2021 - ]
- CHECK HARNESS AND CONNECTOR (ECM - COMBINATION METER ASSEMBLY)
- Disconnect the G16 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A19-41 (LSTM) - G16-34 (LST1) Always Below 1 Ω A19-41 (LSTM) or G16-34 (LST1) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [04/2018 - 08/2020] , or refer to REMOVAL [08/2020 - 08/2021] , or refer to REMOVAL [08/2021 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR