Power Source Circuit [04/2018 -]: Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK HARNESS AND CONNECTOR (POWER SUPPLY)
- Disconnect the 4F instrument panel junction block assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 4F-1 - Body ground Always 8.5 V or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 2
- INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
- Remove the main body ECU (multiplex network body ECU).
Refer to REMOVAL [04/2018 - 08/2021] , or refer to REMOVAL [08/2021 -]
*a Component without harness connected
(Instrument Panel Junction Block Assembly)- - - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 4F-1 - MB-31 (BECU) Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to REMOVAL [04/2018 - 08/2021] , or refer to REMOVAL [08/2021 -]
Result:
NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL [04/2018 - 08/2021] , or refer to REMOVAL [08/2021 -]
- Remove the main body ECU (multiplex network body ECU).