Typical Enabling Conditions
WARNING: This page is about a different variant/trim than selected.
ALL
| Monitor runs whenever the following DTCs are not stored | C121E (Pump motor circuit high) C14D0 (Accumulator pressure sensor voltage circuit check) C14D1 (Accumulator pressure sensor lost communication) C14D2 (Accumulator pressure sensor internal malfunction) C14D3 (Accumulator pressure sensor intermittent/erratic) C14D4 (Case 1) (Accumulator pressure sensor invalid data) C14D4 (Case 2) (Accumulator pressure sensor intermittent) |
CASE 1
| All of the following conditions are met | - |
| Accumulator pressure sensor fail | Not detected |
| Accumulator pressure | Less than 17.1 MPa (174.4 kgf/cm2 , 2480 psi) |
| Brake | Off |
| Brake system voltage 1 (VM1) | Higher than 6.92 V |
CASE 2
| All of the following conditions are met | - |
| Accumulator pressure sensor fail | Not detected |
| Accumulator pressure | Less than 17.1 MPa (174.4 kgf/cm2 , 2480 psi) |
| Pump motor control circuit high | Not detected |
| Brake | Off |
| Brake system voltage 1 (VM1) | Higher than 6.92 V |
CASE 3
| Both of the following conditions are met | - |
| Accumulator pressure sensor fail | Not detected |
| Accumulator pressure | Less than 17.1 MPa (174.4 kgf/cm2 , 2480 psi) |