Component Operating Range
WARNING: This page is about a different variant/trim than selected.
HINT:
SAE code only.
C0562
| Both of the following conditions are met | - |
| Brake system voltage 1 (VM1) | Higher than 6.92 V |
| Brake pedal stroke sensor assembly power supply | 4.74 V or more, and 5.23 V or less |
C124B
| Both of the following conditions are met | - |
| Brake system voltage 1 (VM1) | Higher than 6.92 V |
| Brake pedal stroke sensor assembly state | Valid |
C1392
| Both of the following conditions are met | - |
| Brake pedal stroke sensor 1 zero point calibration value | Stored |
| Brake pedal stroke sensor 2 zero point calibration value | Stored |
P057C, P05DD, P057D AND P05DE
| Both of the following conditions are met | - |
| Brake pedal stroke sensor assembly power supply | 4.74 V or more, and 5.23 V or less |
| Power supply voltage ratio of SKS and VSK | 0.06 or more, and 0.94 or less |
HINT:
The power supply voltage ratio is the ratio of the voltage of SKS1 and VSK1 or SKS2 and VSK2.
P057E AND P05DF
| Both of the following conditions are met | - |
| Brake pedal stroke sensor assembly power supply | 4.74 V or more, and 5.23 V or less |
| Difference between the current power supply voltage ratio and the previous power supply voltage ratio of SKS and VSK | 8.5% or less |
HINT:
The power supply voltage ratio is the ratio of the voltage of SKS1 and VSK1 or SKS2 and VSK2.
P05E0
| Both of the following conditions are met | - |
| Brake system voltage 1 (VM1) | Higher than 6.92 V |
| Brake pedal stroke sensor assembly on experience (low/mid/high) | On |