Typical Malfunction Thresholds
WARNING: This page is about a different variant/trim than selected.
C139A (CASE 1)
| Reaction force pressure | 4.5 MPa (45.9 kgf/cm2 , 653 psi) or more |
C139A (CASE 2)
| Reaction force pressure | 1.5 MPa (15.3 kgf/cm2 , 218 psi) or more |
C139D
| Servo pressure | 0.1 MPa (1 kgf/cm2 , 15 psi) or less |
C13CD (CASE 1)
| Both of the following conditions are met | - |
| Difference between target brake pressure and servo pressure | Higher than 2.7 to 4.14 MPa (27.5 to 42.2 kgf/cm2 , 392 to 601 psi) |
| Delay of servo pressure increase | Higher than 0.3 to 4.128 seconds |
C13CD (CASE 2)
| Both of the following conditions are met | - |
| Difference between target brake pressure and servo pressure | Higher than 1.5 MPa (15.3 kgf/cm2 , 218 psi) |
| Delay of servo pressure increase | Higher than 0.3 to 4.128 seconds |
C13CE (CASE 1 AND 2)
| Both of the following conditions are met | - |
| Difference between servo pressure and target brake pressure | Higher than 1 to 4 MPa (10.2 to 40.8 kgf/cm2 , 145 to 580 psi) |
| Delay of servo pressure decrease | Higher than 0.3 to 2.142 seconds |
C13CE (CASE 3)
| Difference between servo pressure and target brake pressure | Higher than 0.5 MPa (5.1 kgf/cm2 , 73 psi) |
C1400
| All of the following conditions are met | - |
| Servo pressure decrease (a) | Higher than 0.4 MPa (4.1 kgf/cm2 , 58 psi) |
| Gradient of servo pressure (b) | Less than -20 MPa/s |
| Servo pressure increase after ABS pump motor on after malfunction criteria (a) and (b) are met | Higher than 0.5 MPa (5.1 kgf/cm2 , 73 psi) |
| Reduction of time required to ABS pump motor voltage drop below 1.3 V at ABS pump motor voltage on to off compared with no load condition after malfunction criteria (a) and (b) are met | 0.1 seconds or more |
C14EE AND C14F7
| Either of the following conditions is met | A or B |
| A. Both of the following conditions are met | (a) and (b) |
| (a). Reaction force pressure decrease | 0.03 MPa (0.3 kgf/cm2 , 4.4 psi) or more |
| (b). Reaction force pressure after malfunction criteria (a) is met | 0.2 MPa (2 kgf/cm2 , 29 psi) or more |
| B. Both of the following conditions are met | (c) and (d) |
| (c). Reaction force pressure | Less than -0.6 MPa (-6.1 kgf/cm2 , -87 psi) |
| (d). Reaction force pressure after malfunction criteria (c) is met | 0.2 MPa (2 kgf/cm2 , 29 psi) or more |