DTC B1507-18: Turn Signal Light Circuit Current Below Threshold [07/2020 - ]: Procedure
- CHECK SYMPTOMS
- Check the problem symptoms.
Result
Result Proceed to LH side front turn signal light does not blink A LH side rear turn signal light does not blink B RH side front turn signal light does not blink C RH side rear turn signal light does not blink D
Result:
B
See step 7
Result:
C
See step 9
Result:
D
See step 14
Result:
A
See step 2
- Check the problem symptoms.
- CONFIRM MODEL
- Choose the model to be inspected.
Result
Result Proceed to w/ Projector Headlight A w/o Projector Headlight B
Result:
B
See step 4
Result:
A
See step 3
- Choose the model to be inspected.
- CHECK LH SIDE FRONT TURN SIGNAL LIGHT
- Remove the headlight assembly LH and RH.
Refer to REMOVAL [07/2020 - ]
- Interchange the headlight assembly LH with RH and connect the connectors.
- Operate the turn signal switch and check that the LH side front turn signal light operates normally.
Result
Result Proceed to LH side front turn signal light operates normally A Problem symptoms do not change
(LH side front turn signal light does not blink)B
Result:
A
REPLACE HEADLIGHT ASSEMBLY LH. Refer to REMOVAL [07/2020 - ]
Result:
B
See step 5
- Remove the headlight assembly LH and RH.
- INSPECT HEADLIGHT ASSEMBLY LH
Refer to INSPECTION [07/2020 - ]
Result
Proceed to OK NG Result:
NG
See step 6
Result:
OK
See step 5
- CHECK HARNESS AND CONNECTOR (HEADLIGHT ASSEMBLY LH - COMBINATION METER ASSEMBLY AND BODY GROUND)
- Disconnect the A95 headlight assembly LH connector.
- Disconnect the E16 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A95-2 (B) - E16-11 (LL) Always Below 1 Ω A95-6 (E) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [07/2020 - 10/2022] , or refer to REMOVAL [10/2022 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK LH SIDE FRONT TURN SIGNAL LIGHT
- Remove the headlight front turn signal LED LH and RH.
Refer to DISASSEMBLY [07/2020 - ]
- Interchange the headlight front turn signal LED LH with RH and connect the connectors.
- Connect the A95 headlight assembly LH connector.
- Operate the turn signal switch and check that the LH side front turn signal light operates normally.
Result
Result Proceed to LH side front turn signal light operates normally A Problem symptoms do not change
(LH side front turn signal light does not blink)B
Result:
A
REPLACE HEADLIGHT FRONT TURN SIGNAL LED LH. Refer to DISASSEMBLY [07/2020 - ]
Result:
B
REPLACE HEADLIGHT UNIT ASSEMBLY LH. Refer to DISASSEMBLY [07/2020 - ]
- Remove the headlight front turn signal LED LH and RH.
- INSPECT REAR TURN SIGNAL LIGHT LED LH
Refer to INSPECTION [07/2020 - ]
Result
Proceed to OK NG Result:
NG
REPLACE REAR TURN SIGNAL LIGHT LED LH. Refer to DISASSEMBLY [07/2020 - ]
Result:
OK
See step 8
- CHECK HARNESS AND CONNECTOR (REAR TURN SIGNAL LIGHT ASSEMBLY LH - COMBINATION METER ASSEMBLY AND BODY GROUND)
- Disconnect the E16 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition S6-2 (B) - E16-10 (TRNL) Always Below 1 Ω S6-1 (E) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [07/2020 - 10/2022] , or refer to REMOVAL [10/2022 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CONFIRM MODEL
- Choose the model to be inspected.
Result
Result Proceed to w/ Projector Headlight A w/o Projector Headlight B
Result:
B
See step 11
Result:
A
See step 10
- Choose the model to be inspected.
- CHECK RH SIDE FRONT TURN SIGNAL LIGHT
- Remove the headlight assembly RH and LH.
Refer to REMOVAL [07/2020 - ]
- Interchange the headlight assembly RH with LH and connect the connectors.
- Operate the turn signal switch and check that the RH side front turn signal light operates normally.
Result
Result Proceed to RH side front turn signal light operates normally A Problem symptoms do not change
(RH side front turn signal light does not blink)B
Result:
A
REPLACE HEADLIGHT ASSEMBLY RH. Refer to REMOVAL [07/2020 - ]
Result:
B
See step 12
- Remove the headlight assembly RH and LH.
- INSPECT HEADLIGHT FRONT TURN SIGNAL LED RH
Refer to INSPECTION [07/2020 - ]
Result
Proceed to OK NG Result:
NG
See step 13
Result:
OK
See step 12
- CHECK HARNESS AND CONNECTOR (HEADLIGHT ASSEMBLY RH - COMBINATION METER ASSEMBLY AND BODY GROUND)
- Disconnect the A94 headlight assembly RH connector.
- Disconnect the E16 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A94-2 (B) - E16-7 (LR) Always Below 1 Ω A94-6 (E) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [07/2020 - 10/2022] , or refer to REMOVAL [10/2022 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK RH SIDE FRONT TURN SIGNAL LIGHT
- Remove the headlight front turn signal LED RH and LH.
Refer to DISASSEMBLY [07/2020 - ]
- Interchange the headlight front turn signal LED RH with LH and connect the connectors.
- Connect the A94 headlight assembly RH connector.
- Operate the turn signal switch and check that the RH side front turn signal light operates normally.
Result
Result Proceed to RH side front turn signal light operates normally A Problem symptoms do not change
(RH side front turn signal light does not blink)B
Result:
A
REPLACE HEADLIGHT FRONT TURN SIGNAL LED RH. Refer to DISASSEMBLY [07/2020 - ]
Result:
B
REPLACE HEADLIGHT UNIT ASSEMBLY RH. Refer to DISASSEMBLY [07/2020 - ]
- Remove the headlight front turn signal LED RH and LH.
- INSPECT REAR TURN SIGNAL LIGHT LED RH
Refer to INSPECTION [07/2020 - ]
Result
Proceed to OK NG Result:
NG
REPLACE REAR TURN SIGNAL LIGHT LED RH. Refer to DISASSEMBLY [07/2020 - ]
Result:
OK
See step 15
- CHECK HARNESS AND CONNECTOR (REAR TURN SIGNAL LIGHT ASSEMBLY RH - COMBINATION METER ASSEMBLY AND BODY GROUND)
- Disconnect the E16 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition S5-2 (B) - E16-13 (TRNR) Always Below 1 Ω S5-1 (E) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [07/2020 - 10/2022] , or refer to REMOVAL [10/2022 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR