  1. INSTALL NO. 2 AIR CLEANER HOSE 
    1. Check the sealing ring (1) on the No. 2 air cleaner hose (3) for damage and replace it, if necessary.
      GTY946191Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Check the sealing ring (2) on the No. 2 air cleaner hose (3) for damage and replace it, if necessary.
    3. Insert and install No. 2 air cleaner hose.
    4. Lock clamp.

      HINT: 

      The clamp must engage audibly.

    5. Tighten down the T30 bolts.

      Torque: 8.0 N.m (82 kgf/cm, 71 in.lbf) 

    6. Connect connectors (2) and lock.

      HINT: 

      The connector must engage audibly.

      GTY946182Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    7. Connect connectors (1) and lock.

      HINT: 

      The connector must engage audibly.

  2. CONNECT ELECTRIC WATER PUMP ASSEMBLY 
    1. Position the electric water pump assembly.
    2. Insert and install the No. 2 Water Pump bracket sub-assembly.
    3. Tighten nut.

      Torque: 8.0 N.m (82 kgf/cm, 71 in.lbf) 

    4. Connect connectors and lock.
  3. INSTALL AIR CLEANER HOSE ASSEMBLY 

    Refer to INSTALLATION [03/2019 - ]